Bison Gear & Engineering Corporation: OSHA inspections and violations
Downers Grove, Illinois · Speed Changer, Industrial High-Speed Drive, and Gear Manufacturing · NAICS 333612
9inspections
23citation items
$15,970current penalties
Nov 3, 2015last inspection
Bison Gear & Engineering Corporation has 9 OSHA inspections on record in Illinois, the first in 1978.
OSHA's last visit started on Nov 3, 2015 on a referral, in Saint Charles.
Across those inspections OSHA issued 23 citation items: 20 serious and 3 other-than-serious.
OSHA proposed $23,200 in penalties. After settlements and reviews the total is $15,970, down 31%.
Most often, OSHA cited 1910.106, flammable liquids (6 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Bison Gear & Engineering Corporation averages $13,300 over 1 cited inspection in that time.
Bison Gear & Engineering Corporation also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Illinois · latest 90 days of OSHA records
427employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Bison Gear & Engineering Corporation and get notified the morning OSHA posts a new citation for it.
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious
$0
$0
Apr 17, 1978
Closed
Injury and illness logs
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2022, the St. Charles site logged 2 recordable injuries or illnesses among about 286 workers: 1.0 per 100 full-time workers, against a median of 2.1 for its industry. Those cases cost 6 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Bison Gear & Engineering Corp.
St. Charles · 2022
286
2
1
1.0
2.1
Bison Gear and Engineering
St. Charles · 2019
288
10
4
3.7
2.1
Bison Gear and Engineering Corporation
St. Charles · 2017
271
13
5
4.9
2.1
Bge #1
St. Charles · 2016
256
8
5
2.9
2.1
Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Oct 27, 2015, Saint Charles: Amputation · amputations · fingertip(s)
On or about 8:15 a.m. on October 27, 2015, an employee was operating a com cutter machine when he incurred an amputation to the tip of his left ring finger. The machine rotates, smooths and cuts commutators that are a component of DC motors.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
29 CFR 1910.106(d)(4)(v)
(v) Storage in inside storage rooms. In every inside storage room there shall be maintained one clear aisle at least 3 feet wide. Containers over 30 gallons capacity shall not be stacked one upon the other. Dispensing shall be by approved pump or self-closing faucet only.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.