OSHA SearchOSHA records by employer

Brainerd Compressor Rebuilders, Inc: OSHA inspections and violations

Memphis, Tennessee · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

2inspections
14citation items
$3,550current penalties
Jul 14, 2015last inspection

Since 2012, OSHA inspectors have visited Brainerd Compressor Rebuilders, Inc in Tennessee 2 times.

The most recent inspection opened on Jul 14, 2015 as a planned inspection, in Memphis.

In all, OSHA issued 14 citation items: 3 serious and 11 other-than-serious.

The penalties, $3,550 in total, stand where OSHA first set them.

The rule cited most here is 1910.305 (electrical wiring methods), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Brainerd Compressor Rebuilders, Inc averages $1,750 across 1 cited inspection.

Brainerd Compressor Rebuilders, Inc: OSHA citation items per year, 2012 to 2015
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

344employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Brainerd Compressor Rebuilders, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340774215 OPENED JUL 14, 2015Closed

Planned · Complete · Safety · 24 employees at the site · Closed Sep 23, 2015

3034 Sandbrook Drive, Memphis, TN 38116 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,000$1,000Aug 11, 2015Final
Citation 2, item 1
29 CFR 1910.151(b) · First aid and eyewash
Other-than-serious$250$250Aug 11, 2015Final
Citation 2, item 2
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$250$250Aug 11, 2015Final
Citation 2, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$125$125Aug 11, 2015Final
Citation 2, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$125$125Aug 11, 2015Final

Inspection 316389626 OPENED FEB 10, 2012Closed

Planned · Complete · Safety · 28 employees at the site · Closed Apr 9, 2012

3034 Sandbrook St, Memphis, TN 38116 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$750$750Mar 21, 2012Closed
Citation 1, item 2
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$750$750Mar 21, 2012Closed
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$150$150Mar 21, 2012Closed
Citation 2, item 2
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$150$150Mar 21, 2012Closed
Citation 2, item 3
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$0$0Mar 21, 2012Closed
Citation 2, item 4
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Mar 21, 2012Closed
Citation 2, item 5
29 CFR 1910.305(g)(1)(ivd) · Electrical wiring methods
Other-than-serious$0$0Mar 21, 2012Closed
Citation 2, item 6
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Mar 21, 2012Closed
Citation 2, item 7
29 CFR 90007
Other-than-serious$0$0Mar 21, 2012Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(b)

(b) In the absence of an infirmary, clinic, or hospital in near proximity to the workplace which is used for the treatment of all injured employees, a person or persons shall be adequately trained to render first aid. Adequate first aid supplies shall be readily available.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.305 · Electrical wiring methods

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Tennessee