Inspection 346405277 OPENED DEC 20, 2022Closed
101 Andrews Avenue, Youngstown, OH 44503 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Youngstown, Ohio · Fabricated Structural Metal Manufacturing · NAICS 332312
Since 2015, OSHA inspectors have visited Brilex Industries Inc. in Ohio 4 times.
The most recent inspection opened on Dec 20, 2022 on a referral, in Youngstown.
In all, OSHA issued 10 citation items: 9 serious and 1 other-than-serious.
The proposed penalties came to $57,270; today they stand at $36,102, 37% less.
The rule cited most here is 1910.134 (respiratory protection), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Brilex Industries Inc. averages $12,034 across 3 cited inspections.
1 inspection on this page followed a fatal incident.
Brilex Industries Inc. also files yearly injury logs with OSHA, summarized below.
It reported 3 severe injuries to OSHA since 2015.
Ohio · latest 90 days of OSHA records
265employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Ohio
Checking a subcontractor, a client or your own company? Watch Brilex Industries Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company101 Andrews Avenue, Youngstown, OH 44503 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
101 Andrews Avenue, Youngstown, OH 44503 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(1)(i)(b) · Electrical equipment, general requirements |
Serious | $4,351 | $4,351 | May 3, 2022 | Final |
101 Andrews Avenue, Youngstown, OH 44503 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Feb 4, 2021 (fatal): Employee is killed when asphyxiated while wearing supplied a
At 5:00 p.m. on February 4, 2021, an employee was working for a firm that manufactured fabricated structural metal. He was performing abrasive blasting with steel shot. He was wearing a supplied air respirator (SAR). While using the supplied air hood, he lost consciousness. A pressure testing operation downstream on the plant air line allowed nitrogen to backfill into the compressed air line. This test introduced an asphyxiant into the system. The employee was killed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $12,288 | $12,288 | May 27, 2021 | Final |
| Citation 1, item 1b 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | May 27, 2021 | Final |
| Citation 1, item 1c 29 CFR 1910.134(k)(3) · Respiratory protection |
Serious | $0 | $0 | May 27, 2021 | Final |
| Citation 1, item 2 29 CFR 1910.134(i)(7) · Respiratory protection |
Serious | $8,778 | $7,543 | May 27, 2021 | Final |
| Citation 1, item 3a 29 CFR 1910.134(i)(1)(ii) · Respiratory protection |
Other-than-serious | $13,653 | $1,000 | May 27, 2021 | Final |
1201 Crescent Street, Youngstown, OH 44501 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $3,500 | $2,100 | Jun 22, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $4,900 | $2,940 | Jun 22, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.179(n)(3)(iii)(b) · Overhead and gantry cranes |
Serious | $4,900 | $2,940 | Jun 22, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $4,900 | $2,940 | Jun 22, 2015 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Youngstown site logged 1 recordable injury or illness among about 79 workers: 1.2 per 100 full-time workers, against a median of 3.6 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Brilex Industries, Inc. P1 Youngstown · 2025 | 79 | 1 | 0 | 1.2 | 3.6 |
| Brilex Industries, Inc P2 Youngstown · 2025 | 54 | 2 | 0 | 3.4 | 3.6 |
| Brilex Industries, Inc P1 Youngstown · 2021 | 79 | 3 | 0 | 3.3 | 3.6 |
| Brilex Industries, Inc. P2 Youngstown · 2017 | 26 | 1 | 1 | 2.3 | 3.6 |
Included with any plan: 16 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.
Dec 14, 2022, Youngstown: Hospitalization · fractures · multiple leg locations, n.e.c.
An employee was welding steel pieces that are approximately 120 inches in length, 90 inches wide, and 12 inches tall. An overhead crane was moving a part when the part fell and struck the employee's right leg. The employee was hospitalized with fractures to the femur and fibula.
Dec 14, 2020, Youngstown: Hospitalization · intracranial injuries, unspecified · brain
An employee was painting when he tripped and fell 11 inches, hitting his head on a skid steer. He suffered a head injury and was hospitalized.
Apr 28, 2015, Youngstown: Hospitalization · soreness, pain, hurt-nonspecified injury · foot (feet), unspecified
A worker was in the process of moving a large round plate off of the top of the fixture when the plate became stuck on one of the mounting bolts. The plate then shifted, swung around the fixture, toppled over, and struck the worker in the left foot.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
29 CFR 1910.134(i)(1)(ii)
(ii) Compressed breathing air shall meet at least the requirements for Grade D breathing air described in ANSI/Compressed Gas Association Commodity Specification for Air, G-7.1-1989, to include:
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.