OSHA has inspected Brown Distributing Company Ltd 6 times in Texas since 1998.

The latest one began on Feb 25, 2015 as a planned inspection, in Austin.

Those inspections ended with 30 citation items: 19 serious and 11 other-than-serious.

Penalties were first proposed at $24,693 and now stand at $14,816, 40% lower after settlements or reviews.

Electrical equipment, general requirements comes up most often in these citations: 7 items under 1910.303.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,425, and Brown Distributing Company Ltd averages $11,070 (1 cited inspection).

Brown Distributing Company Ltd also files yearly injury logs with OSHA, summarized below.

Brown Distributing Company Ltd: OSHA citation items per year, 1998 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Brown Distributing Company Ltd and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340428366 OPENED FEB 25, 2015Closed

Planned · Complete · Safety · 320 employees at the site · Closed Apr 29, 2015

8711 Johnny Morris Road, Austin, TX 78724 · Beer and Ale Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$4,000$2,400Apr 13, 2015Final
Citation 1, item 2
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,000$1,800Apr 13, 2015Final
Citation 1, item 3a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,000$3,000Apr 13, 2015Final
Citation 1, item 3b
29 CFR 1910.212(b) · Machine guarding
Serious$0$0Apr 13, 2015Final
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$2,550$1,530Apr 13, 2015Final
Citation 1, item 5a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$3,400$2,040Apr 13, 2015Final
Citation 1, item 5b
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$0$0Apr 13, 2015Final
Citation 1, item 5c
29 CFR 1910.303(g)(1)(i)(a) · Electrical equipment, general requirements
Serious$0$0Apr 13, 2015Final
Citation 1, item 5d
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Apr 13, 2015Final
Citation 1, item 5e
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Apr 13, 2015Final
Citation 2, item 1a
29 CFR 1904.29(b)(1) · Injury and illness log
Other-than-serious$500$300Apr 13, 2015Final
Citation 2, item 1b
29 CFR 1904.32(b)(6) · Yearly injury summary
Other-than-serious$0$0Apr 13, 2015Final

Inspection 311309082 OPENED SEP 14, 2007Closed

Referral · Partial · Health · 35 employees at the site · Closed Feb 12, 2008

2201 Barton Springs Rd (zilker Park), Austin, TX 78746 · Beer and Ale Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309757649 OPENED FEB 22, 2007Closed

Planned · Complete · Safety · 340 employees at the site · Closed Feb 27, 2007

8711 Johnny Morris Rd, Austin, TX 78724 · Beer and Ale Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306061888 OPENED APR 2, 2003Closed

Planned · No inspection · Health · 365 employees at the site · Closed Apr 7, 2003

8711 Johnny Morris Rd, Austin, TX 78724 · Beer and Ale Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302337886 OPENED OCT 20, 1998Closed

Planned · Complete · Health · 209 employees at the site · Closed Jan 21, 1999

411 Chicon Street, Austin, TX 78702 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$1,125$675Nov 23, 1998Closed
Citation 1, item 1b
29 CFR 1910.138(a) · Gloves and hand protection
Serious$0$0Nov 23, 1998Closed
Citation 1, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,125$675Nov 23, 1998Closed
Citation 1, item 2b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Nov 23, 1998Closed
Citation 2, item 1
29 CFR 1904.2(a)(2) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Nov 23, 1998Closed
Citation 2, item 2
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Nov 23, 1998Closed
Citation 2, item 3
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Nov 23, 1998Closed

Inspection 302338009 OPENED OCT 20, 1998Closed

Planned · Complete · Safety · 209 employees at the site · Closed Jan 7, 1999

411 Chicon Street, Austin, TX 78702 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Serious$956$574Nov 23, 1998Closed
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$956$574Nov 23, 1998Closed
Citation 1, item 3
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$956$574Nov 23, 1998Closed
Citation 1, item 4a
29 CFR 1910.38(a)(1) · Emergency action plans
Serious$1,125$675Nov 23, 1998Closed
Citation 1, item 4b
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Nov 23, 1998Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Nov 23, 1998Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Nov 23, 1998Closed
Citation 2, item 3
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Nov 23, 1998Closed
Citation 2, item 4
29 CFR 1910.303(c) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 23, 1998Closed
Citation 2, item 5
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 23, 1998Closed
Citation 2, item 6
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 23, 1998Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Austin site logged 18 recordable injuries or illnesses among about 443 workers: 3.7 per 100 full-time workers, against a median of 4.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Brown Distributing Company, LTD
Austin · 2025
443 1803.74.7

Included with any plan: 6 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.2(a)(2)

(2) If one or more of your company's establishments are classified in a non-exempt industry, you must keep OSHA injury and illness records for all of such establishments unless your company is partially exempted because of size under § 1904.1.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(1)

(b) Implementation—(1) What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(b)(6)

(6) When do I have to post the annual summary? You must post the summary no later than February 1 of the year following the year covered by the records and keep the posting in place until April 30.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

OSH Act Section 5 · General Duty Clause

Other beer and ale merchant wholesalers employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.