OSHA SearchOSHA records by employer

Carlson Engineered Composites USA Inc: OSHA inspections and violations

St Cloud, Minnesota · All Other Plastics Product Manufacturing · NAICS 326199

3inspections
10citation items
$4,605current penalties
Jun 29, 2016last inspection

Carlson Engineered Composites USA Inc has 3 OSHA inspections on record in Minnesota, the first in 2013.

OSHA's last visit started on Jun 29, 2016 as a planned inspection, in Saint Cloud.

Across those inspections OSHA issued 10 citation items: 5 serious, 1 repeat and 4 other-than-serious.

OSHA proposed $5,550 in penalties. After settlements and reviews the total is $4,605, down 17%.

Most often, OSHA cited 5206.700, (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Carlson Engineered Composites USA Inc averages $2,400 over 1 cited inspection in that time.

Carlson Engineered Composites USA Inc: OSHA citation items per year, 2013 to 2016
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

369employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Carlson Engineered Composites USA Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341591618 OPENED JUN 29, 2016Closed

Planned · Complete · Safety · 56 employees at the site · Closed Aug 9, 2016

4751 Heatherwood Rd, Saint Cloud, MN 56301 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 182.653(08)
Repeat$1,500$1,500Jul 15, 2016Final
Citation 2, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$750$750Jul 15, 2016Final
Citation 3, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$150$150Jul 15, 2016Final

Inspection 317749513 OPENED MAY 27, 2014Closed

Follow-up · Partial · Health · 65 employees at the site · Closed Oct 13, 2014

4751 Heatherwood Rd, St Cloud, MN 56301 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317404457 OPENED NOV 13, 2013Closed

Referral · Partial · Health · 52 employees at the site · Closed Aug 7, 2014

4751 Heatherwood Rd, St Cloud, MN 56301 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$300$210Jan 15, 2014Final
Citation 1, item 2
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$750$525Jan 15, 2014Final
Citation 1, item 3
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$900$630Jan 15, 2014Final
Citation 1, item 4 Serious$900$630Jan 15, 2014Final
Citation 2, item 1
29 CFR 1904.29(a) · Injury and illness log
Other-than-serious$0$0Jan 15, 2014Final
Citation 2, item 2 Other-than-serious$300$210Jan 15, 2014Final
Citation 2, item 3 Other-than-serious$0$0Jan 15, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(a)

(a) Basic requirement. You must use OSHA 300, 300-A, and 301 forms, or equivalent forms, for recordable injuries and illnesses. The OSHA 300 form is called the Log of Work-Related Injuries and Illnesses, the 300-A is the Summary of Work-Related Injuries and Illnesses, and the OSHA 301 form is called the Injury and Illness Incident Report.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.133(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(a)(2)

(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 5205.116

29 CFR 5206.700

Other all other plastics product manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.