OSHA SearchOSHA records by employer

Casco Signs, Inc.: OSHA inspections and violations

Kannapolis, North Carolina · Sign Manufacturing · NAICS 339950

7inspections
59citation items
$10,530current penalties
Sep 10, 2024last inspection

Since 2002, OSHA inspectors have visited Casco Signs, Inc. in North Carolina 7 times.

The most recent inspection opened on Sep 10, 2024 as a planned inspection, in Concord.

In all, OSHA issued 59 citation items: 23 serious, 2 repeat and 34 other-than-serious.

The proposed penalties came to $13,950; today they stand at $10,530, 25% less.

The rule cited most here is 1910.1200 (hazard communication), 12 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Casco Signs, Inc. averages $1,850 across 2 cited inspections.

Casco Signs, Inc. also files yearly injury logs with OSHA, summarized below.

Casco Signs, Inc.: OSHA citation items per year, 2002 to 2024
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Casco Signs, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347747065 OPENED SEP 10, 2024Closed

Planned · Complete · Health · 40 employees at the site · Closed Mar 4, 2025

199 Wilshire Ave Sw,, Concord, NC 28025 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,300$1,300Jan 22, 2025Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$750$750Jan 22, 2025Final
Citation 2, item 1
29 CFR 1910.133(a)(3) · Eye and face protection
Other-than-serious$0$0Jan 22, 2025Final
Citation 2, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 22, 2025Final
Citation 2, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 22, 2025Final
Citation 2, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$750$750Jan 22, 2025Final
Citation 2, item 4b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Jan 22, 2025Final
Citation 2, item 4c
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Jan 22, 2025Final
Citation 2, item 4d
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jan 22, 2025Final

Inspection 343082889 OPENED APR 12, 2018Closed

Planned · Complete · Health · 48 employees at the site · Closed Jul 9, 2018

199 Wilshire Ave. Sw, Concord, NC 28026 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.29(b)(1) · Fall protection systems in general industry
Serious$450$450May 2, 2018Final
Citation 1, item 1b
29 CFR 1910.29(b)(2)(i) · Fall protection systems in general industry
Serious$0$0May 2, 2018Final
Citation 2, item 1
29 CFR 1910.36(d)(1) · Exit route design
Other-than-serious$0$0May 2, 2018Final
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0May 2, 2018Final
Citation 2, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$450$450May 2, 2018Final

Inspection 317842557 OPENED OCT 8, 2014Closed

Planned · Partial · Health · 2 employees at the site · Closed Jan 9, 2015

750 Timber Drive, Garner, NC 27529 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,000$1,300Nov 6, 2014Closed
Citation 1, item 2a
29 CFR 1926.251(a)(1) · Rigging equipment for material handling
Serious$2,000$1,300Nov 6, 2014Closed
Citation 1, item 2b
29 CFR 1926.251(a)(2)(i) · Rigging equipment for material handling
Serious$0$0Nov 6, 2014Closed
Citation 1, item 2c
29 CFR 1926.1416(e)(1) · Operational aids
Serious$0$0Nov 6, 2014Closed
Citation 1, item 2d Serious$0$0Nov 6, 2014Closed
Citation 1, item 3a
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,200$780Nov 6, 2014Closed
Citation 1, item 3b
29 CFR 1926.501(b)(2)(ii) · Fall protection in construction
Serious$0$0Nov 6, 2014Closed
Citation 1, item 3c
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Nov 6, 2014Closed
Citation 1, item 3d
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Nov 6, 2014Closed

Inspection 317215317 OPENED JUL 29, 2013Closed

Accident · Partial · Safety · 1 employee at the site · Closed Aug 22, 2013

7706 North Tryon Street, Charlotte, NC 28262 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jul 29, 2013: Employee falls into trench and is injured

On July 29, 2013, Employee #1 was digging underneath a newly installed conduit, which needed to be located deeper in a trench. He was working outside the trench and he tripped over the conduit and fell into the trench. As he fell, he struck his head against the asphalt pavement. The trench was narrow enough for him, wh ere he became stuck in the trench and could not conduct a self-rescue. Emergency medical personnel were summoned. They arrived and rescued him from the trench a nd transported him to a medical center. At the medical center, he was treated fo r head and chest contusions and then hospitalized.

No citations from this inspection.

Inspection 311814032 OPENED JAN 7, 2008Closed

Planned · Complete · Health · 23 employees at the site · Closed Apr 23, 2009

1638 S. Ridge Ave., Kannapolis, NC 28082 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(g)(8) · Hazard communication
Repeat$100$100May 23, 2008Closed
Citation 1, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Repeat$100$100May 23, 2008Closed
Citation 2, item 1
29 CFR 1910.23(e)(2) · Guarding floor and wall openings and holes
Serious$250$150May 23, 2008Closed
Citation 2, item 2a Serious$2,100$1,350May 23, 2008Closed
Citation 2, item 2b Serious$0$0May 23, 2008Closed
Citation 2, item 2c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0May 23, 2008Closed
Citation 2, item 3
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$500$350May 23, 2008Closed
Citation 2, item 4
29 CFR 1910.212(a)(5) · Machine guarding
Serious$700$450May 23, 2008Closed
Citation 2, item 5
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$350$250May 23, 2008Closed
Citation 2, item 6
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$700$450May 23, 2008Closed
Citation 3, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 2
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 3
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 4
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 5
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 6
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 7
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 8
29 CFR 1910.1052(d)(2) · Methylene chloride
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 9
29 CFR 1910.1052(l)(1) · Methylene chloride
Other-than-serious$0$0May 23, 2008Closed
Citation 3, item 10
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0May 23, 2008Closed

Inspection 309517266 OPENED JUN 7, 2006Closed

Planned · Complete · Safety · 20 employees at the site · Closed Jul 14, 2006

265 Eastchester Dr. - Harris-teeter #341, High Point, NC 27262 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$250$250Jun 14, 2006Closed
Citation 1, item 1b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jun 14, 2006Closed
Citation 2, item 1
29 CFR 1926.150(a)(4) · Fire protection
Other-than-serious$0$0Jun 14, 2006Closed
Citation 2, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 14, 2006Closed
Citation 2, item 2b
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jun 14, 2006Closed
Citation 2, item 2c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jun 14, 2006Closed

Inspection 305623043 OPENED OCT 16, 2002Closed

Planned · Complete · Health · 20 employees at the site · Closed Jan 20, 2003

1638 South Ridge Road, Kannapolis, NC 28082 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 2
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 3
29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 4
29 CFR 1910.38(a)(2) · Emergency action plans
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 5
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 6
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 7
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 8
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 9
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Nov 1, 2002Closed
Citation 1, item 10
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Nov 1, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Concord site logged 0 recordable injuries or illnesses among about 42 workers: 0.0 per 100 full-time workers, against a median of 0.1 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Casco Signs INC
Concord · 2025
42 000.00.1

Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.1052 · Methylene chloride

29 CFR 1910.1052(d)(2)

(2) Initial determination. Each employer whose employees are exposed to MC shall perform initial exposure monitoring to determine each affected employee's exposure, except under the following conditions:

29 CFR 1910.1052(l)(1)

(l) Employee information and training. (1) The employer shall provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to MC.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.94 · Ventilation

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1416 · Operational aids

29 CFR 1926.1417 · Operation

29 CFR 1926.150 · Fire protection

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other sign manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.