OSHA SearchOSHA records by employer

Ceadda, Inc.: OSHA inspections and violations

Grand Junction, Colorado · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

1inspections
16citation items
$2,026current penalties
May 6, 2025last inspection

Ceadda, Inc. has one OSHA inspection on record in Colorado.

OSHA opened it on May 6, 2025 as a planned inspection, in Grand Junction.

From that inspection OSHA issued 16 citation items: 2 serious and 14 other-than-serious.

OSHA proposed $3,376 in penalties. After settlements and reviews the total is $2,026, down 40%.

Most often, OSHA cited 1910.134, respiratory protection (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Ceadda, Inc. averages $2,026 over 1 cited inspection in that time.

Ceadda, Inc. also files yearly injury logs with OSHA, summarized below.

Ceadda, Inc.: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Ceadda, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348229014 OPENED MAY 6, 2025Closed

Planned · Complete · Health · 13 employees at the site · Closed Jan 5, 2026

682 W Gunnison Ave, Grand Junction, CO 81501 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(ii)(b)(2) · Flammable liquids
Serious$1,447$868Sep 30, 2025Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,929$1,157Sep 30, 2025Final
Citation 2, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 1b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 3b
29 CFR 1910.134(d)(3)(iii)(b)(1) · Respiratory protection
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 3c
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 3d
29 CFR 1910.134(e)(6)(i) · Respiratory protection
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 3e
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 4
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 6b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 6c
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Sep 30, 2025Final
Citation 2, item 6d
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Sep 30, 2025Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Grand Junction site logged 3 recordable injuries or illnesses among about 18 workers: 18.2 per 100 full-time workers, against a median of 4.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
CeAdda, Inc
Grand Junction · 2023
18 3018.24.6
CeAdda Inc
Grand Junction · 2021
18 000.04.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)(b)(2)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

Other wood kitchen cabinet and countertop manufacturing employers in Colorado

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.