OSHA SearchOSHA records by employer

Cedar Township-Road District: OSHA inspections and violations

Abingdon, Illinois · Other Support Activities for Road Transportation · NAICS 488490

1inspections
6citation items
$0current penalties
Jun 16, 2015last inspection

Cedar Township-Road District has one OSHA inspection on record in Illinois.

OSHA opened it on Jun 16, 2015 as a planned inspection, in Abingdon.

From that inspection OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.106, flammable liquids (3 items).

For context, across all transportation and warehousing employers the median penalty per cited inspection since 2015 is $2,415. Cedar Township-Road District averages $0 over 1 cited inspection in that time.

Cedar Township-Road District: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Cedar Township-Road District and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340710052 OPENED JUN 16, 2015Closed

Planned · Complete · Safety · Local government · 2 employees at the site · Closed Oct 14, 2015

303 E. 1st Street, Abingdon, IL 61410 · Other Support Activities for Road Transportation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(g)(3)(iv)(d) · Flammable liquids
Serious$0$0Sep 17, 2015Final
Citation 1, item 2
29 CFR 1910.106(g)(8) · Flammable liquids
Serious$0$0Sep 17, 2015Final
Citation 1, item 3
29 CFR 1910.106(g)(9) · Flammable liquids
Serious$0$0Sep 17, 2015Final
Citation 1, item 4
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Sep 17, 2015Final
Citation 1, item 5
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Sep 17, 2015Final
Citation 2, item 1
29 CFR 56 IL ADMIN CODE PART 350.260(A)
Other-than-serious$0$0Sep 17, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(3)(iv)(d)

(iv) Dispensing units. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be transferred from tanks by means of fixed pumps so designed and equipped as to allow control of the flow and to prevent leakage or accidental discharge.

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.106(g)(9)

(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other other support activities for road transportation employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.