OSHA SearchOSHA records by employer

Cedar Welding and Fabrication Inc.: OSHA inspections and violations

Cedar City, Utah · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

2inspections
11citation items
$1,875current penalties
Aug 23, 2018last inspection

Cedar Welding and Fabrication Inc. has 2 OSHA inspections on record in Utah, the first in 2008.

OSHA's last visit started on Aug 23, 2018 as a planned inspection, in Cedar City.

Across those inspections OSHA issued 11 citation items: 11 serious.

OSHA proposed $4,500 in penalties. After settlements and reviews the total is $1,875, down 58%.

Most often, OSHA cited 1910.134, respiratory protection (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Cedar Welding and Fabrication Inc. averages $375 over 1 cited inspection in that time.

Cedar Welding and Fabrication Inc.: OSHA citation items per year, 2008 to 2018
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

73employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Cedar Welding and Fabrication Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343411237 OPENED AUG 23, 2018Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 5, 2018

642 N 1070 W, Cedar City, UT 84721 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$750$375Aug 29, 2018Final

Inspection 310460266 OPENED APR 15, 2008Closed

Planned · Complete · Safety · 5 employees at the site · Closed Aug 5, 2008

673 N 800 W, Cedar City, UT 84720 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$1,500$600May 13, 2008Closed
Citation 1, item 1b
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$0$0May 13, 2008Closed
Citation 1, item 1c
29 CFR 1910.107(d)(1) · Spray painting and finishing
Serious$0$0May 13, 2008Closed
Citation 1, item 2a
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$1,500$600May 13, 2008Closed
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0May 13, 2008Closed
Citation 1, item 2c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0May 13, 2008Closed
Citation 1, item 2d
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0May 13, 2008Closed
Citation 1, item 3
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$375$150May 13, 2008Closed
Citation 1, item 4a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$375$150May 13, 2008Closed
Citation 1, item 4b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0May 13, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(d)(1)

(d) Ventilation—(1) Conformance. Ventilating and exhaust systems shall be in accordance with the Standard for Blower and Exhaust Systems for Vapor Removal, NFPA No. 91-1961, which is incorporated by reference as specified in § 1910.6, where applicable and shall also conform to the provisions of this section.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels