OSHA SearchOSHA records by employer

Champion Iron Works, Inc.: OSHA inspections and violations

Berryville, Virginia · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

6inspections
22citation items
$3,675current penalties
Jan 25, 2019last inspection

Champion Iron Works, Inc. has 6 OSHA inspections on record in Virginia, the first in 2001.

OSHA's last visit started on Jan 25, 2019 as a planned inspection, in Berryville.

Across those inspections OSHA issued 22 citation items: 15 serious and 7 other-than-serious.

OSHA proposed $3,675 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Champion Iron Works, Inc. averages $1,200 over 1 cited inspection in that time.

Champion Iron Works, Inc.: OSHA citation items per year, 2001 to 2019
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Champion Iron Works, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343736997 OPENED JAN 25, 2019Closed

Planned · Complete · Safety · 19 employees at the site · Closed Mar 29, 2019

509 Jack Enders Blvd, Berryville, VA 22611 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$600$600Mar 5, 2019Final
Citation 1, item 2a
29 CFR 1910.303(g)(1)(i)(a) · Electrical equipment, general requirements
Serious$600$600Mar 5, 2019Final
Citation 1, item 2b
29 CFR 1910.303(b)(8)(iii) · Electrical equipment, general requirements
Serious$0$0Mar 5, 2019Final
Citation 1, item 2c
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Mar 5, 2019Final
Citation 1, item 2d
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Mar 5, 2019Final
Citation 1, item 2e
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Mar 5, 2019Final
Citation 1, item 2f
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Mar 5, 2019Final
Citation 2, item 1
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$0$0Mar 5, 2019Final

Inspection 315825513 OPENED JUL 20, 2011Closed

Planned · Partial · Safety · 8 employees at the site · Closed Sep 15, 2011

3000 Chain Bridge Road, Oakton, VA 22124 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR FPSE076020 A
Serious$875$875Aug 10, 2011Closed
Citation 1, item 1b
29 CFR FPSE07603002
Serious$0$0Aug 10, 2011Closed
Citation 1, item 2
29 CFR 1926.350(b)(3) · Gas welding and cutting
Serious$525$525Aug 10, 2011Closed
Citation 1, item 3a Serious$525$525Aug 10, 2011Closed
Citation 1, item 3b
29 CFR 1926.1412(f)(2) · Inspections
Serious$0$0Aug 10, 2011Closed

Inspection 312754542 OPENED NOV 6, 2008Closed

Planned · Complete · Safety · 20 employees at the site · Closed Feb 19, 2009

509 Jack Enders Blvd, Berryville, VA 22611 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(g)(3)(vb) · Flammable liquids
Serious$225$225Dec 18, 2008Closed
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$225$225Dec 18, 2008Closed
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Dec 18, 2008Closed
Citation 2, item 2
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Dec 18, 2008Closed
Citation 2, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Dec 18, 2008Closed
Citation 2, item 4
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 18, 2008Closed
Citation 2, item 5
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Dec 18, 2008Closed

Inspection 311601009 OPENED DEC 10, 2007Closed

Planned · Complete · Health · 40 employees at the site · Closed Dec 11, 2007

509 Jack Enders Blvd, Berryville, VA 22611 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306816554 OPENED NOV 20, 2003Closed

Planned · Complete · Health · 19 employees at the site · Closed Dec 16, 2003

509 Jack Enders Blvd, Berryville, VA 22611 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$100$100Dec 2, 2003Closed
Citation 2, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Dec 2, 2003Closed

Inspection 304775711 OPENED DEC 10, 2001Closed

Planned · Complete · Safety · 1 employee at the site · Closed Dec 10, 2001

509 Jack Enders Blvd, Berryville, VA 22611 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(3)(vb)

(v) Remote pumping systems. (a) This paragraph (g)(3)(v) shall apply to systems for dispensing Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), where such liquids are transferred from storage to individual or multiple dispensing units by pumps located elsewhere than at the dispensing units.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(5)(ii)

(ii) The label for bulk shipments of hazardous chemicals must be on the immediate container, transmitted with the shipping papers or the bills of lading, or, with the agreement of the receiving entity, transmitted by technological or electronic means so that it is immediately available to workers in printed form on the receiving end of shipment.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1926.1412 · Inspections

29 CFR 1926.1417 · Operation

29 CFR 1926.350 · Gas welding and cutting

Other ornamental and architectural metal work manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.