OSHA SearchOSHA records by employer

Champlain Cable Corporation: OSHA inspections and violations

Colchester, Vermont · Other Communication and Energy Wire Manufacturing · NAICS 335929

14inspections
66citation items
$25,074current penalties
Dec 20, 2019last inspection

OSHA has inspected Champlain Cable Corporation 14 times in Vermont since 1983.

The latest one began on Dec 20, 2019 after a fatality or catastrophe, in Colchester.

Those inspections ended with 66 citation items: 25 serious, 1 repeat and 40 other-than-serious.

Penalties were first proposed at $43,913 and now stand at $25,074, 43% lower after settlements or reviews.

Electrical equipment, general requirements comes up most often in these citations: 6 items under 1910.303.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Champlain Cable Corporation averages $11,934 (1 cited inspection).

Champlain Cable Corporation also files yearly injury logs with OSHA, summarized below.

Champlain Cable Corporation: OSHA citation items per year, 1983 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Champlain Cable Corporation again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344524178 OPENED DEC 20, 2019Closed

Fatality or catastrophe · Partial · Safety · 240 employees at the site · Closed Jul 16, 2020

175 Hercules Drive, Colchester, VT 05446 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Dec 20, 2019: Employee's arm is amputated after hand is caught in spool

At 11:20 a.m. on December 20, 2019, an employee was working for a firm that manufactured cable for communications and energy transmission. She was working as a machine operator, or "spark test" operator. She was working on the take up side of line 3510 at the firm's facility. She was operating a Sterling Davis Electric model PORA spooling machine, with serial number C3390. It ran on 480 volts. She was using it take up the firm's catalog number 3XWR5 XLE 0.327-inch-diameter (about AWG gauge 0) wire, onto spool number 974181408. The spool was 18 in. (0.46 meters) in diameter. It was 26.5 in. (0.67 meters) above the ground. She was standing approximately 6 in. (150 mm) from the spool on the take up side of line 3510. Workers generally stood some 6 to 12 in. (150 to 300 mm) from the cable. The employee was standing her distance from the spool because of her height and ability to reach the wire. She was guiding the cable by hand. Her hand was pulled into the spool. The wire continued to spool at a low rpm, while the employee was wrapped in it three times. She was stuck under the cabling machine, and her arm was amputated. She was hospitalized. The employee stated that her left hand was directly touching the wire. She stated that she had been trained to use her hand on top of the wire to guide it into place. She stated the wire was sticky and that her left hand stuck to the wire. She was unable to move her hand, and it was pulled into the spool. She was working alone at the time of the incident, and no one witnessed it. Employee interviews revealed that this practice of employees using their hands to guide cable onto the automatically turning wheels was common and expected by the employer, even though it exposed them to obvious point of operation hazards. The employee spent herentire shift in an unguarded machine area.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$11,934$11,934Jun 16, 2020Final
Citation 1, item 1b
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$11,934$0Jun 16, 2020Final

Inspection 308609775 OPENED JAN 23, 2007Closed

Complaint · Partial · Health · 135 employees at the site · Closed May 31, 2007

Hercules Drive, Colchester, VT 05446 · Noncurrent-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.138(b) · Gloves and hand protection
Other-than-serious$0$0May 10, 2007Closed
Citation 1, item 2
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0May 10, 2007Closed

Inspection 305535825 OPENED MAY 17, 2004Closed

Planned · Complete · Safety · 106 employees at the site · Closed Nov 1, 2004

175 Hercules Lane, Colchester, VT 05446 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$1,300$1,300Jul 1, 2004Closed
Citation 1, item 1b
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$0$0Jul 1, 2004Closed
Citation 1, item 1c
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jul 1, 2004Closed
Citation 1, item 1d
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Jul 1, 2004Closed
Citation 1, item 1e
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Jul 1, 2004Closed
Citation 2, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$0$0Jul 1, 2004Closed
Citation 2, item 2
29 CFR 1910.106(e)(7)(ic) · Flammable liquids
Other-than-serious$0$0Jul 1, 2004Closed
Citation 2, item 3
29 CFR 1910.110(f)(7) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jul 1, 2004Closed

Inspection 305529810 OPENED OCT 10, 2002Closed

Complaint · Partial · Health · 117 employees at the site · Closed Mar 6, 2003

12 Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(2)(ii) · Hazard communication
Other-than-serious$0$0Feb 7, 2003Closed

Inspection 305530545 OPENED OCT 10, 2002Closed

Complaint · Partial · Safety · 117 employees at the site · Closed Jan 27, 2003

12 Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,925$1,400Dec 5, 2002Closed
Citation 1, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$1,100$600Dec 5, 2002Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Dec 5, 2002Closed
Citation 2, item 2
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$0$0Dec 5, 2002Closed

Inspection 302365051 OPENED MAR 4, 1999Closed

Planned · No inspection · Safety · 172 employees at the site · Closed Mar 4, 1999

12 Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 124430141 OPENED NOV 18, 1998Closed

Complaint · Partial · Health · 175 employees at the site · Closed Jul 13, 1999

12 Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Apr 23, 1999Closed
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Apr 23, 1999Closed

Inspection 111717591 OPENED APR 19, 1993Closed

Planned · Complete · Safety · 211 employees at the site · Closed Sep 15, 1993

Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$900$900May 3, 1993Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$675$675May 3, 1993Closed
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$2,250$2,250May 3, 1993Closed
Citation 1, item 3b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 3, 1993Closed
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$675$675May 3, 1993Closed
Citation 2, item 1
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$0$0May 3, 1993Closed
6 older inspections

Inspection 105666424 OPENED AUG 30, 1989Closed

Accident · Complete · Health · 310 employees at the site · Closed Apr 18, 1991

Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 30033 A
Serious$2,000$1,000Feb 28, 1990Contested
Citation 1, item 2a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$1,600$900Feb 28, 1990Contested
Citation 1, item 2b
29 CFR 1910.141(g)(2) · Sanitation
Serious$0$0Feb 28, 1990Contested
Citation 1, item 3a
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$1,600$900Feb 28, 1990Contested
Citation 1, item 3b
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Feb 28, 1990Contested
Citation 1, item 4a
29 CFR 1910.1200(f)(4)(i) · Hazard communication
Serious$1,440$700Feb 28, 1990Contested
Citation 1, item 4b
29 CFR 1910.1200(f)(4)(ii) · Hazard communication
Serious$0$0Feb 28, 1990Contested
Citation 1, item 5
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$960$300Feb 28, 1990Contested
Citation 1, item 6
29 CFR 1910.1200(h) · Hazard communication
Serious$1,800$900Feb 28, 1990Contested
Citation 2, item 1 Other-than-serious$0$0Feb 28, 1990Contested
Citation 2, item 2
29 CFR 1910.1025(l)(2)(i) · Lead in general industry
Other-than-serious$0$0Feb 28, 1990Contested

Inspection 105660930 OPENED JUN 8, 1989Closed

Complaint · Partial · Safety · 300 employees at the site · Closed Sep 7, 1989

Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$480$0Jun 16, 1989Closed

Inspection 105646723 OPENED MAR 22, 1988Closed

Complaint · Partial · Health · 310 employees at the site · Closed Jun 1, 1988

12 Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Repeat$160$160May 18, 1988Closed

Inspection 18683045 OPENED JAN 5, 1987Closed

Planned · Complete · Safety · 365 employees at the site · Closed Jun 16, 1987

Industrial Park, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$480$480Jan 27, 1987Closed
Citation 2, item 1
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 2
29 CFR 1910.106(d)(7)(ia) · Flammable liquids
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 3
29 CFR 1910.106(d)(7)(iii) · Flammable liquids
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 4
29 CFR 1910.106(e)(2)(iib) · Flammable liquids
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 5
29 CFR 1910.106(e)(6)(iii) · Flammable liquids
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 6
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 7
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 8
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 9
29 CFR 1910.178(m)(6)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 10
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 11
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 12
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 13
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 14
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 15
29 CFR 1910.305(f) · Electrical wiring methods
Other-than-serious$0$0Jan 27, 1987Closed
Citation 2, item 16
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jan 27, 1987Closed

Inspection 15209653 OPENED JUN 19, 1985Closed

Complaint · Partial · Health · 405 employees at the site · Closed Apr 15, 1987

Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 30223 A
Serious$700$0Dec 18, 1985Contested
Citation 2, item 1 Other-than-serious$0$0Dec 18, 1985Contested
Citation 2, item 2 Other-than-serious$0$0Dec 18, 1985Contested
Citation 2, item 3 Other-than-serious$0$0Dec 18, 1985Contested

Inspection 10689107 OPENED NOV 22, 1983Closed

Planned · Complete · Safety · 299 employees at the site · Closed Dec 13, 1983

Hercules Drive, Colchester, VT 05446 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(d)(2) · Portable fire extinguishers
Other-than-serious$0$0Dec 6, 1983Closed
Citation 1, item 2
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Dec 6, 1983Closed
Citation 1, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Dec 6, 1983Closed
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Dec 6, 1983Closed
Citation 1, item 5
29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment
Other-than-serious$0$0Dec 6, 1983Closed
Citation 1, item 6
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Dec 6, 1983Closed
Citation 1, item 7
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Dec 6, 1983Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Colchester site logged 0 recordable injuries or illnesses among about 116 workers: 0.0 per 100 full-time workers, against a median of 1.5 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Champlain Cable Corporation
Colchester · 2025
116 000.01.5

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(l)(2)(i)

(2) Access to information and training materials. (i) The employer shall make readily available to all affected employees a copy of this standard and its appendices.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(7)(ia)

(7) Fire control—(i) Extinguishers. Suitable fire control devices, such as small hose or portable fire extinguishers, shall be available at locations where flammable liquids are stored.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.20

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other other communication and energy wire manufacturing employers in Vermont

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.