Clark Industrial Services, LLC.: OSHA inspections and violations

Freeport, Texas · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · NAICS 811310

1inspections
4citation items
$13,526current penalties
Jan 16, 2019last inspection

OSHA has inspected Clark Industrial Services, LLC. once in Texas.

The inspection began on Jan 16, 2019 as part of a related case, in Freeport.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $13,526 and still stand at $13,526.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Clark Industrial Services, LLC. averages $13,526 (1 cited inspection).

Clark Industrial Services, LLC.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Clark Industrial Services, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343740148 OPENED JAN 16, 2019Closed

Unprogrammed related · Partial · Safety · 14 employees at the site · Closed Dec 26, 2019

505 Port Rd., Freeport, TX 77541 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$6,763$6,763May 3, 2019Final
Citation 1, item 1b
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0May 3, 2019Final
Citation 1, item 1c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0May 3, 2019Final
Citation 1, item 2
29 CFR 1910.307(c)(2)(i) · Hazardous (classified) locations
Serious$6,763$6,763May 3, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.307(c)(2)(i)

(2) Approved for the hazardous (classified) location. (i) Equipment shall be approved not only for the class of location, but also for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that will be present.

29 CFR 1910.332 · Training

29 CFR 1910.332(b)(2)

(2) Additional requirements for unqualified persons. Employees who are covered by paragraph (a) of this section but who are not qualified persons shall also be trained in and familiar with any electrically related safety practices not specifically addressed by §§ 1910.331 through 1910.335 but which are necessary for their safety.

29 CFR 1910.334 · Using electrical equipment

Other commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.