OSHA SearchOSHA records by employer

Clyde Bergemann Power Group, Inc.: OSHA inspections and violations

Jesup, Georgia · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · NAICS 333411

3inspections
8citation items
$5,998current penalties
Feb 16, 2016last inspection

Since 2013, OSHA inspectors have visited Clyde Bergemann Power Group, Inc. in Georgia 3 times.

The most recent inspection opened on Feb 16, 2016 after a complaint, in Jesup.

In all, OSHA issued 8 citation items: 2 serious and 6 other-than-serious.

The proposed penalties came to $8,140; today they stand at $5,998, 26% less.

The rule cited most here is 1910.134 (respiratory protection), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Clyde Bergemann Power Group, Inc. averages $1,000 across 1 cited inspection.

Clyde Bergemann Power Group, Inc.: OSHA citation items per year, 2013 to 2016
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

150employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Clyde Bergemann Power Group, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341262715 OPENED FEB 16, 2016Closed

Complaint · Partial · Safety · 460 employees at the site · Closed May 4, 2016

201 Tank Road, Jesup, GA 31545 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.32(a)(4) · Yearly injury summary
Other-than-serious$1,000$1,000Feb 23, 2016Final

Inspection 339069429 OPENED MAY 15, 2013Closed

Complaint · Partial · Health · 114 employees at the site · Closed Dec 5, 2013

201 Tank Road, Jesup, GA 31545 · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Oct 28, 2013Final
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Oct 28, 2013Final
Citation 1, item 2b
29 CFR 1910.134(k)(3) · Respiratory protection
Other-than-serious$0$0Oct 28, 2013Final
Citation 1, item 3
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Oct 28, 2013Final

Inspection 339107062 OPENED MAY 15, 2013Closed

Complaint · Partial · Safety · 119 employees at the site · Closed Dec 5, 2013

201 Tank Road, Jesup, GA 31545 · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$2,890$2,023Oct 28, 2013Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$4,250$2,975Oct 28, 2013Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 28, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(4)

(4) Post the annual summary.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.95 · Noise

Other ventilation, heating, air-conditioning, and commercial refrigeration equipment manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.