Inspection 347351470 OPENED MAR 13, 2024Closed
2120 Industrial Blvd, Harlingen, TX 78553 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1983, OSHA inspectors have visited CMC Steel Fabricators, Inc. in Texas 14 times.
The most recent inspection opened on Mar 13, 2024 as a planned inspection, in Harlingen.
In all, OSHA issued 16 citation items: 9 serious and 7 other-than-serious.
The proposed penalties came to $54,570; today they stand at $34,465, 37% less.
The rule cited most here is 1910.212 (machine guarding), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. CMC Steel Fabricators, Inc. averages $17,180 across 2 cited inspections.
It reported 2 severe injuries to OSHA since 2015.
The Wage and Hour Division has 1 case on it since 2015, with $3,338 in back wages owed to workers.
Texas · latest 90 days of OSHA records
399employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch CMC Steel Fabricators, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company2120 Industrial Blvd, Harlingen, TX 78553 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
15019 Interstate 35, Buda, TX 78610 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Nov 17, 2021: Employee suffers fingertip amputations while bending rebar
At 1:45 p.m. on November 17, 2021, an employee was bending rebar on a table bender to create a product called standees. The employee was not using the hands-free tool or clamps to hold the rebar but instead was using his hands, as was common practice. As part of a hands-free initiative, the employer provided clamps to secure the rebar when passing through the machine to prevent rebar from slipping. The clamps were provided with the additional purpose to keep operators hands away pinch points associated with performing table bending. The employee was holding down rebar while it was bending when his glove was pinched between the rebar and the ram. The employee suffered amputations of the fingertips of his left hand and was treated without hospitalization.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(iii) · Machine guarding |
Other-than-serious | $10,360 | $10,360 | Feb 16, 2022 | Final |
301 W. Foxshire, Houston, TX 77053 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2a 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $7,000 | $7,000 | Jun 1, 2016 | Final |
| Citation 1, item 2b 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $7,000 | $0 | Jun 1, 2016 | Final |
| Citation 1, item 3a 29 CFR 1910.184(d) · Slings |
Serious | $4,000 | $3,000 | Jun 1, 2016 | Final |
| Citation 1, item 3b 29 CFR 1910.184(i)(9) · Slings |
Serious | $4,000 | $0 | Jun 1, 2016 | Final |
| Citation 1, item 5 29 CFR 1910.212(a)(3)(iii) · Machine guarding |
Serious | $7,000 | $7,000 | Jun 1, 2016 | Final |
| Citation 1, item 6 29 CFR 1910.212(b) · Machine guarding |
Serious | $5,000 | $4,000 | Jun 1, 2016 | Final |
| Citation 1, item 7a 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $5,000 | $3,000 | Jun 1, 2016 | Final |
| Citation 1, item 7b 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $5,000 | $0 | Jun 1, 2016 | Final |
2001 Brittmore Rd., Houston, TX 77043 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
20 N. Stefens St., Dallas, TX 75247 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Aloe Field, Victoria, TX 77901 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
300 Bill Dwyer Rd, Seguin, TX 78155 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7800 N. Stemmons Frwy, Dallas, TX 75247 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Aloe Field, Victoria, TX 77901 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7800 N. Stemmons Frwy, Dallas, TX 75247 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 E. Crestwood, Victoria, TX 77902 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 E. Crestwood, Victoria, TX 77902 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 E. Crestwood, Victoria, TX 77902 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $210 | $105 | Apr 20, 1987 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Apr 20, 1987 | Closed |
| Citation 2, item 2 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 20, 1987 | Closed |
| Citation 2, item 3 29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Apr 20, 1987 | Closed |
| Citation 2, item 4 29 CFR 1910.179(m)(1) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Apr 20, 1987 | Closed |
| Citation 2, item 5 29 CFR 1910.252(b)(4)(ixc) · Welding fire safety |
Other-than-serious | $0 | $0 | Apr 20, 1987 | Closed |
| Citation 2, item 6 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 20, 1987 | Closed |
5908 All Day, Houston, TX 77036 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
May 24, 2016, Houston: Amputation · amputations · finger(s), fingernail(s), n.e.c.
An employee was bending rebar and turned the switch to the program position so he could check the angle of the bar. The bending pin went to the left side of the bar. As he turned the equipment back on in the manual mode, the bending pin returned to the home position. The employee had already loaded a second bar. When the bending pin was returning to the home position, it picked up the second…
Apr 14, 2016, Buda: Amputation · amputations · finger(s), fingernail(s), unspecified
An employee was bending rebar when part of his little finger was amputated.
Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
| Period reviewed | Violations | Workers owed | Back wages | Penalties |
|---|---|---|---|---|
| Jan 4, 2019 to Nov 7, 2019 Dallas | 11 | 5 | $3,338 | $0 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.147(c)(4)(ii)
(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.