Inspection 346111685 OPENED JUL 29, 2022Closed
1316 Yacht Drive, Chesapeake, VA 23320 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Chesapeake, Virginia · Other Concrete Product Manufacturing · NAICS 327390
OSHA has inspected Coastal Precast Systems, LLC 9 times in Virginia since 2012.
The latest one began on Jul 29, 2022 on a referral, in Chesapeake.
Those inspections ended with 83 citation items: 72 serious, 1 willful and 10 other-than-serious.
Penalties were first proposed at $242,996 and now stand at $76,902, 68% lower after settlements or reviews.
Electrical wiring methods comes up most often in these citations: 7 items under 1910.305.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Coastal Precast Systems, LLC averages $10,398 (7 cited inspections).
1 inspection on this page followed a fatal incident.
Coastal Precast Systems, LLC also files yearly injury logs with OSHA, summarized below.
Virginia · latest 90 days of OSHA records
246employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Coastal Precast Systems, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company1316 Yacht Drive, Chesapeake, VA 23320 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1134 Bay Shore Road, Cape Charles, VA 23310 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 16VAC25-60-120 |
Serious | $6,170 | $3,085 | Jan 4, 2021 | Final |
| Citation 1, item 2a 29 CFR 1910.184(c)(14) · Slings |
Serious | $6,170 | $3,085 | Jan 4, 2021 | Final |
| Citation 1, item 2b 29 CFR 1910.184(d) · Slings |
Serious | $0 | $0 | Jan 4, 2021 | Final |
| Citation 1, item 2c 29 CFR 1910.184(e)(3)(ii) · Slings |
Serious | $0 | $0 | Jan 4, 2021 | Final |
| Citation 1, item 2d 29 CFR 1910.184(f)(5)(iii) · Slings |
Serious | $0 | $0 | Jan 4, 2021 | Final |
1316 Yacht Drive, Chesapeake, VA 23320 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.30(a)(1) · Training requirements |
Serious | $12,470 | $6,235 | Jul 2, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.30(a)(3)(i) · Training requirements |
Serious | $0 | $0 | Jul 2, 2018 | Final |
| Citation 1, item 1c 29 CFR 1910.30(a)(3)(iii) · Training requirements |
Serious | $0 | $0 | Jul 2, 2018 | Final |
| Citation 1, item 1d 29 CFR 1910.30(a)(3)(iv) · Training requirements |
Serious | $0 | $0 | Jul 2, 2018 | Final |
| Citation 1, item 1e 29 CFR 1910.30(d) · Training requirements |
Serious | $0 | $0 | Jul 2, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.1200(h)(3)(iii) · Hazard communication |
Serious | $7,680 | $3,840 | Jul 2, 2018 | Final |
1316 Yacht Drive, Chesapeake, VA 23320 · Marine Cargo Handling · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1917.26(d)(1) · First aid and lifesaving facilities |
Serious | $8,908 | $5,790 | Oct 14, 2016 | Final |
| Citation 1, item 1b 29 CFR 1917.26(f) · First aid and lifesaving facilities |
Serious | $0 | $0 | Oct 14, 2016 | Final |
| Citation 1, item 1c 29 CFR 1917.30(a)(1) · Emergency action plans |
Serious | $0 | $0 | Oct 14, 2016 | Final |
| Citation 1, item 2 29 CFR 1917.42(h)(3)(ii) · Miscellaneous auxiliary gear |
Serious | $7,126 | $4,632 | Oct 14, 2016 | Final |
| Citation 1, item 4 29 CFR 1917.50(a) · Certification of marine terminal material handling devices (See also mandatory appendix I, of this part) |
Serious | $7,126 | $4,632 | Oct 14, 2016 | Final |
| Citation 1, item 5 29 CFR 1917.112(b)(1) · Guarding of edges |
Serious | $12,471 | $8,106 | Oct 14, 2016 | Final |
1316 Yacht Drive, Chesapeake, VA 23320 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $3,840 | $2,688 | Oct 20, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Oct 20, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Oct 20, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.146(c)(4) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Oct 20, 2016 | Final |
| Citation 2, item 4 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Oct 20, 2016 | Final |
1316 Yacht Drive, Chesapeake, VA 23320 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 16VAC25-60-120 |
Serious | $5,600 | $2,800 | Oct 18, 2016 | Final |
| Citation 1, item 2a 29 CFR 1910.22(a)(1) · General requirements |
Serious | $3,840 | $1,920 | Oct 18, 2016 | Final |
| Citation 1, item 2b 29 CFR 1910.22(b)(1) · General requirements |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 2c 29 CFR 1910.22(d)(1) · General requirements |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 2d 29 CFR 1910.22(c) · General requirements |
Serious | $5,040 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 2e 29 CFR 1910.23(a)(8)(ii) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 2f 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 2g 29 CFR 1910.23(d)(1) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 2h 29 CFR 1910.26(c)(2)(iv) · Portable metal ladders |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 2i 29 CFR 1910.26(c)(2)(vii) · Portable metal ladders |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 2j 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $5,040 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 4a 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $5,040 | $2,520 | Oct 18, 2016 | Final |
| Citation 1, item 4b 29 CFR 1910.36(h)(4) · Exit route design |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 4c 29 CFR 1910.37(a)(1) · Exit routes |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 4d 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 5a 29 CFR 1910.106(d)(6)(i) · Flammable liquids |
Serious | $5,040 | $2,520 | Oct 18, 2016 | Final |
| Citation 1, item 5b 29 CFR 1910.106(g)(3)(iv)(d) · Flammable liquids |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 7 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $5,600 | $2,800 | Oct 18, 2016 | Final |
| Citation 1, item 9a 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $5,040 | $2,520 | Oct 18, 2016 | Final |
| Citation 1, item 9b 29 CFR 1910.212(b) · Machine guarding |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 9c 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 9d 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 10a 29 CFR 1910.252(b)(2)(i)(a) · Welding fire safety |
Serious | $5,040 | $2,520 | Oct 18, 2016 | Final |
| Citation 1, item 10b 29 CFR 1910.252(b)(2)(i)(b) · Welding fire safety |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 10c 29 CFR 1910.252(b)(2)(iii) · Welding fire safety |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 10d 29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 10f 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 10g 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $5,040 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $5,600 | $2,800 | Oct 18, 2016 | Final |
| Citation 1, item 11b 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11c 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11d 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11e 29 CFR 1910.305(a)(2)(x) · Electrical wiring methods |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11f 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11g 29 CFR 1910.305(b)(3)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11h 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11i 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11j 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11k 29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 1, item 11l 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 2, item 1a 29 CFR 1910.141(c)(1)(i) · Sanitation |
Other-than-serious | $1,040 | $0 | Oct 18, 2016 | Final |
| Citation 2, item 1b 29 CFR 1910.141(c)(2)(i) · Sanitation |
Other-than-serious | $0 | $0 | Oct 18, 2016 | Final |
| Citation 2, item 1c 29 CFR 1910.141(d)(1) · Sanitation |
Other-than-serious | $0 | $0 | Oct 18, 2016 | Final |
1316 Yacht Drive, Chesapeake, VA 23320 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Apr 19, 2016 (fatal): Employee is struck and killed by mobile-wheeled crane
At approximately 8:45 a.m. on April 19, 2016, Employee #1 was standing in the yard area while waiting for an area to clear. He was traveling to the area to aid in its cleanup. As he was waiting, a mobile-wheeled gantry crane struck him with one of its tires and caused crushing injuries over his body. Employee #1 was killed from those traumatic crushing injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 40.1-51.1.A |
Serious | $6,300 | $3,150 | Oct 13, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes |
Serious | $3,300 | $0 | Oct 13, 2016 | Final |
| Citation 1, item 1c 29 CFR 1910.179(m)(1) · Overhead and gantry cranes |
Serious | $0 | $0 | Oct 13, 2016 | Final |
| Citation 1, item 1d 29 CFR 1910.180(d)(4) · Crawler locomotive and truck cranes |
Serious | $4,800 | $0 | Oct 13, 2016 | Final |
| Citation 1, item 1e 29 CFR 1910.180(d)(6) · Crawler locomotive and truck cranes |
Serious | $0 | $0 | Oct 13, 2016 | Final |
| Citation 1, item 1f 29 CFR 1910.180(h)(3)(ix) · Crawler locomotive and truck cranes |
Serious | $6,300 | $0 | Oct 13, 2016 | Final |
| Citation 1, item 2a 29 CFR 16VAC25-60-120 |
Serious | $6,300 | $3,150 | Oct 13, 2016 | Final |
| Citation 1, item 2b 29 CFR 16VAC25-60-120 |
Serious | $7,000 | $0 | Oct 13, 2016 | Final |
| Citation 1, item 2c 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Willful | $55,000 | $0 | Oct 13, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks |
Serious | $4,800 | $2,400 | Oct 13, 2016 | Final |
| Citation 1, item 8a 29 CFR 1910.184(e)(1) · Slings |
Other-than-serious | $3,300 | $0 | Oct 13, 2016 | Final |
| Citation 1, item 8b 29 CFR 1910.184(e)(3)(ii) · Slings |
Other-than-serious | $0 | $0 | Oct 13, 2016 | Final |
| Citation 3, item 1 29 CFR 16VAC25-60-120 |
Other-than-serious | $0 | $0 | Oct 13, 2016 | Final |
1316 Yacht Drive, Chesapeake, VA 23320 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a) · Machine guarding |
Serious | $2,275 | $1,592 | May 26, 2015 | Final |
2613 Yacht Drive, Chesapeake, VA 23320 · Concrete Block and Brick Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR VAC0120 |
Serious | $4,900 | $1,372 | Sep 25, 2012 | Closed |
| Citation 1, item 2 29 CFR 1910.178(q)(1) · Forklifts and other powered industrial trucks |
Serious | $4,900 | $1,372 | Sep 25, 2012 | Closed |
| Citation 1, item 3a 29 CFR 1910.179(b)(3) · Overhead and gantry cranes |
Serious | $4,900 | $1,372 | Sep 25, 2012 | Closed |
| Citation 1, item 3b 29 CFR 1910.179(l)(3)(i) · Overhead and gantry cranes |
Serious | $0 | $0 | Sep 25, 2012 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Chesapeake site logged 1 recordable injury or illness among about 200 workers: 0.5 per 100 full-time workers, against a median of 3.4 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Coastal Precast System Chesapeake · 2025 | 200 | 1 | 0 | 0.5 | 3.4 |
Included with any plan: 1 more yearly log from these sites, back to 2024, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(6)(i)
(6) Storage outside buildings—(i) General. Storage outside buildings shall be in accordance with Table H-16 or H-17, and subdivisions (ii) and (iv) of this subparagraph.
29 CFR 1910.106(g)(3)(iv)(d)
(iv) Dispensing units. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be transferred from tanks by means of fixed pumps so designed and equipped as to allow control of the flow and to prevent leakage or accidental discharge.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.