OSHA SearchOSHA records by employer

Columbia Contracting, Inc.: OSHA inspections and violations

San Antonio, Texas · All Other Specialty Trade Contractors · NAICS 238990

2inspections
4citation items
$3,790current penalties
Feb 9, 2016last inspection

Columbia Contracting, Inc. has 2 OSHA inspections on record in Texas, the first in 1991.

OSHA's last visit started on Feb 9, 2016 on a referral, in San Antonio.

Across those inspections OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

OSHA proposed $6,400 in penalties. After settlements and reviews the total is $3,790, down 41%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Columbia Contracting, Inc. averages $2,940 over 1 cited inspection in that time.

Columbia Contracting, Inc.: OSHA citation items per year, 1991 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Columbia Contracting, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341239077 OPENED FEB 9, 2016Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jun 10, 2016

849 E Commerce St., San Antonio, TX 78205 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.352(e) · Fire prevention
Serious$4,900$2,940May 27, 2016Final

Inspection 110037538 OPENED AUG 8, 1991Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 28, 1991

502 Durango St, San Antonio, TX 78207 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(5) · Scaffolds, general requirements
Serious$375$200Sep 27, 1991Closed
Citation 1, item 2
29 CFR 1926.451(e)(10) · Scaffolds, general requirements
Serious$875$500Sep 27, 1991Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$250$150Sep 27, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1926.352 · Fire prevention

29 CFR 1926.352(e)

(e) When the welding, cutting, or heating operation is such that normal fire prevention precautions are not sufficient, additional personnel shall be assigned to guard against fire while the actual welding, cutting, or heating operation is being performed, and for a sufficient period of time after completion of the work to ensure that no possibility of fire exists. Such personnel shall be instructed as to the specific anticipated fire hazards and how the firefighting equipment provided is to be used.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(10)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other all other specialty trade contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.