OSHA SearchOSHA records by employer

Concept Plastics, Inc.: OSHA inspections and violations

High Point, North Carolina · Custom Compounding of Purchased Resins · NAICS 325991

11inspections
70citation items
$14,938current penalties
May 4, 2016last inspection

Concept Plastics, Inc. has 11 OSHA inspections on record in North Carolina, the first in 1985.

OSHA's last visit started on May 4, 2016 as a planned inspection, in High Point.

Across those inspections OSHA issued 70 citation items: 23 serious and 47 other-than-serious.

OSHA proposed $22,638 in penalties. After settlements and reviews the total is $14,938, down 34%.

Most often, OSHA cited 1910.212, machine guarding (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Concept Plastics, Inc. averages $3,150 over 1 cited inspection in that time.

Concept Plastics, Inc.: OSHA citation items per year, 1985 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Concept Plastics, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341469393 OPENED MAY 4, 2016Closed

Planned · Complete · Health · 49 employees at the site · Closed Sep 15, 2016

1210 Hickory Chapel Road, High Point, NC 27261 · Custom Compounding of Purchased Resins · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$750$750Jul 6, 2016Final
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,500$1,500Jul 6, 2016Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jul 6, 2016Final
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 6, 2016Final
Citation 2, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 6, 2016Final
Citation 2, item 4
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Jul 6, 2016Final
Citation 2, item 5
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$450$450Jul 6, 2016Final
Citation 2, item 6
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$450$450Jul 6, 2016Final

Inspection 314186164 OPENED APR 8, 2010Closed

Follow-up · Partial · Health · 65 employees at the site · Closed May 7, 2010

1218 Hickory Chapel Rd., High Point, NC 27261 · Custom Compounding of Purchased Resins · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313600157 OPENED OCT 28, 2009Closed

Planned · Complete · Health · 65 employees at the site · Closed Mar 9, 2011

1218 Hickory Chapel Rd., High Point, NC 27261 · Custom Compounding of Purchased Resins · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,100$1,400Dec 16, 2009Closed
Citation 1, item 2
29 CFR 1910.22(a)(1) · General requirements
Serious$2,100$0Dec 16, 2009Closed
Citation 1, item 3a
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$1,500$1,000Dec 16, 2009Closed
Citation 1, item 3b
29 CFR 1910.106(d)(2)(iii) · Flammable liquids
Serious$0$0Dec 16, 2009Closed
Citation 1, item 4
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,500$0Dec 16, 2009Closed
Citation 1, item 5
29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags
Serious$2,100$1,400Dec 16, 2009Closed
Citation 1, item 6
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$900$0Dec 16, 2009Closed
Citation 1, item 7
29 CFR 1910.212(a)(1) · Machine guarding
Serious$900$600Dec 16, 2009Closed
Citation 1, item 8
29 CFR 1910.212(b) · Machine guarding
Serious$900$600Dec 16, 2009Closed
Citation 1, item 9
29 CFR 1910.242(b) · Hand and power tools
Serious$2,100$1,400Dec 16, 2009Closed
Citation 2, item 1
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Dec 16, 2009Closed
Citation 2, item 2
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Dec 16, 2009Closed
Citation 2, item 3
29 CFR 1910.176(b) · Material storage and aisles
Other-than-serious$0$0Dec 16, 2009Closed
Citation 2, item 4
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 16, 2009Closed
Citation 2, item 5
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Dec 16, 2009Closed

Inspection 308558824 OPENED JUL 27, 2005Closed

Complaint · Partial · Safety · 195 employees at the site · Closed Sep 29, 2005

121 East Green Drive, High Point, NC 27260 · Custom Compounding of Purchased Resins · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.138(b) · Gloves and hand protection
Other-than-serious$225$225Aug 23, 2005Closed
Citation 1, item 1b
29 CFR 1910.132(c) · Personal protective equipment, general requirements
Other-than-serious$0$0Aug 23, 2005Closed
Citation 1, item 1c
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Aug 23, 2005Closed

Inspection 307445171 OPENED APR 21, 2004Closed

Planned · Complete · Health · 147 employees at the site · Closed May 20, 2004

1218 Hickory Chapel Rd., High Point, NC 27261 · Custom Compounding of Purchased Resins · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$438$438May 7, 2004Closed
Citation 1, item 2a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$875$875May 7, 2004Closed
Citation 1, item 2b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0May 7, 2004Closed
Citation 2, item 1
29 CFR 7F0102
Other-than-serious$0$0May 7, 2004Closed
Citation 2, item 2a
29 CFR 1910.23(d)(1)(v) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 7, 2004Closed
Citation 2, item 2b
29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 7, 2004Closed
Citation 2, item 3
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0May 7, 2004Closed
Citation 2, item 4
29 CFR 1910.145(f)(3) · Specifications for accident prevention signs and tags
Other-than-serious$0$0May 7, 2004Closed
Citation 2, item 5
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0May 7, 2004Closed
Citation 2, item 6
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0May 7, 2004Closed
Citation 2, item 7
29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection
Other-than-serious$0$0May 7, 2004Closed
Citation 2, item 8
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0May 7, 2004Closed

Inspection 303845127 OPENED JAN 31, 2001Closed

Complaint · Partial · Health · 13 employees at the site · Closed Apr 24, 2001

1218 Hickory Chapel Rd., High Point, NC 27261 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$1,750$1,750Mar 12, 2001Closed
Citation 1, item 1b
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Mar 12, 2001Closed
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 12, 2001Closed
Citation 2, item 2a
29 CFR 1910.133(a)(2) · Eye and face protection
Other-than-serious$0$0Mar 12, 2001Closed
Citation 2, item 2b
29 CFR 1910.133(a)(3) · Eye and face protection
Other-than-serious$0$0Mar 12, 2001Closed
Citation 2, item 3a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Mar 12, 2001Closed
Citation 2, item 3b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Mar 12, 2001Closed
Citation 2, item 3c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Other-than-serious$0$0Mar 12, 2001Closed
Citation 2, item 4
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 12, 2001Closed
Citation 2, item 5a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Mar 12, 2001Closed
Citation 2, item 5b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Mar 12, 2001Closed

Inspection 125290387 OPENED DEC 12, 1994Closed

Complaint · Partial · Health · 120 employees at the site · Closed Mar 28, 1995

2657 E. Green Dr., High Point, NC 27262 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Feb 27, 1995Closed
Citation 1, item 1b
29 CFR 1910.134(b)(3) · Respiratory protection
Other-than-serious$0$0Feb 27, 1995Closed
Citation 1, item 1c
29 CFR 1910.134(b)(11) · Respiratory protection
Other-than-serious$0$0Feb 27, 1995Closed
Citation 1, item 2
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Feb 27, 1995Closed
Citation 1, item 3a
29 CFR 1910.213(p)(4) · Woodworking machinery
Other-than-serious$0$0Feb 27, 1995Closed
Citation 1, item 3b
29 CFR 1910.213(p)(4) · Woodworking machinery
Other-than-serious$0$0Feb 27, 1995Closed
Citation 1, item 4a
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Feb 27, 1995Closed
Citation 1, item 4b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Feb 27, 1995Closed
Citation 1, item 5
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Feb 27, 1995Closed

Inspection 3036449 OPENED OCT 11, 1988Closed

Follow-up · Partial · Health · 120 employees at the site · Closed Apr 17, 1989

2631f Green Drive, High Point, NC 27261 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

3 older inspections

Inspection 3025632 OPENED SEP 19, 1986Closed

Follow-up · Partial · Safety · 100 employees at the site · Closed Dec 2, 1986

2631 E Green Dr, High Point, NC 27261 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7C0101 A99 E1
Other-than-serious$0$0Nov 24, 1986Closed

Inspection 2967206 OPENED DEC 11, 1985Closed

Complaint · Partial · Safety · 100 employees at the site · Closed Dec 2, 1986

2631 E Green Dr, High Point, NC 27261 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(c)(2)(iii) · Forklifts and other powered industrial trucks
Serious$420$420Mar 12, 1986Final
Citation 1, item 2
29 CFR 1910.212(a)(4) · Machine guarding
Serious$300$300Mar 12, 1986Final
Citation 1, item 3
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$300$300Mar 12, 1986Closed
Citation 1, item 4
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$480$480Mar 12, 1986Closed

Inspection 2995462 OPENED DEC 11, 1985Closed

Complaint · Complete · Health · 100 employees at the site · Closed Apr 17, 1989

2631 E Green Dr, High Point, NC 27261 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$300$300Apr 17, 1986Closed
Citation 1, item 1b
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Apr 17, 1986Closed
Citation 1, item 2 Serious$300$300Apr 17, 1986Closed
Citation 2, item 1
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0Apr 17, 1986Closed
Citation 2, item 2
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$0$0Apr 17, 1986Closed
Citation 2, item 3a
29 CFR 1910.141(g)(2) · Sanitation
Other-than-serious$0$0Apr 17, 1986Closed
Citation 2, item 3b
29 CFR 1910.141(g)(4) · Sanitation
Other-than-serious$0$0Apr 17, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(d)(2)(iii)

(iii) Size. Flammable liquid containers shall be in accordance with Table H-12, except that glass or plastic containers of no more than 1-gallon capacity may be used for a Category 1 or 2 flammable liquid if:

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.334 · Using electrical equipment

29 CFR 9501.2901

Other custom compounding of purchased resins employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.