OSHA SearchOSHA records by employer

Confab Inc: OSHA inspections and violations

Kaysville, Utah · Other Concrete Product Manufacturing · NAICS 327390

5inspections
32citation items
$2,000current penalties
Dec 12, 2019last inspection

Confab Inc has 5 OSHA inspections on record in Utah, the first in 1995.

OSHA's last visit started on Dec 12, 2019 as a planned inspection, in Layton.

Across those inspections OSHA issued 32 citation items: 19 serious and 13 other-than-serious.

OSHA proposed $6,075 in penalties. After settlements and reviews the total is $2,000, down 67%.

Most often, OSHA cited 1910.95, noise (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Confab Inc averages $250 over 1 cited inspection in that time.

Confab Inc: OSHA citation items per year, 1995 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Confab Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344505540 OPENED DEC 12, 2019Closed

Planned · Partial · Safety · 20 employees at the site · Closed Jan 17, 2020

882 N Marshall Way, Layton, UT 84041 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$375$250Jan 2, 2020Final

Inspection 310460084 OPENED MAR 25, 2008Closed

Complaint · Complete · Health · 15 employees at the site · Closed Sep 4, 2008

882 N Marshall Way, Layton, UT 84041 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$375$22Jul 21, 2008Closed
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jul 21, 2008Closed
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jul 21, 2008Closed
Citation 1, item 1d
29 CFR 1910.134(k)(3) · Respiratory protection
Serious$0$0Jul 21, 2008Closed
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,500$89Jul 21, 2008Closed
Citation 1, item 3a
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$1,500$89Jul 21, 2008Closed
Citation 1, item 3b
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Serious$0$0Jul 21, 2008Closed
Citation 1, item 3c
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Jul 21, 2008Closed
Citation 1, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$375$23Jul 21, 2008Closed
Citation 1, item 4b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jul 21, 2008Closed
Citation 2, item 1
29 CFR 1910.38(a) · Emergency action plans
Other-than-serious$150$9Jul 21, 2008Closed
Citation 2, item 2a Other-than-serious$150$9Jul 21, 2008Closed
Citation 2, item 2b Other-than-serious$0$0Jul 21, 2008Closed
Citation 2, item 2c Other-than-serious$0$0Jul 21, 2008Closed
Citation 2, item 2d Other-than-serious$0$0Jul 21, 2008Closed
Citation 2, item 3a
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$150$9Jul 21, 2008Closed
Citation 2, item 3b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Jul 21, 2008Closed

Inspection 126748540 OPENED AUG 11, 1995Closed

Referral · Partial · Health · 12 employees at the site · Closed Aug 11, 1995

267 North 650 West, Kaysville, UT 84037 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126746734 OPENED JUN 26, 1995Closed

Follow-up · Partial · Safety · 12 employees at the site · Closed Jun 26, 1995

267 North 650 West, Kaysville, UT 84037 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126745744 OPENED MAY 22, 1995Closed

Planned · Complete · Safety · 12 employees at the site · Closed Dec 31, 1995

267 North 650 West, Kaysville, UT 84037 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$500$500Jun 6, 1995Closed
Citation 1, item 1b
29 CFR 1910.212(a)(5) · Machine guarding
Serious$0$0Jun 6, 1995Closed
Citation 1, item 1c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 6, 1995Closed
Citation 1, item 1d
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 6, 1995Closed
Citation 1, item 1e
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$0$0Jun 6, 1995Closed
Citation 1, item 2a
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Serious$500$500Jun 6, 1995Closed
Citation 1, item 2b
29 CFR 1910.27(d)(1)(ii) · Fixed ladders
Serious$0$0Jun 6, 1995Closed
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$500$500Jun 6, 1995Closed
Citation 2, item 1
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0Jun 6, 1995Closed
Citation 2, item 2
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 6, 1995Closed
Citation 2, item 3
29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 6, 1995Closed
Citation 2, item 4
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 6, 1995Closed
Citation 2, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jun 6, 1995Closed
Citation 2, item 6
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jun 6, 1995Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.95 · Noise

29 CFR 4040.1820

Other other concrete product manufacturing employers in Utah

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.