Construction Implements Depot, Inc.: OSHA inspections and violations

Denton, North Carolina · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

2inspections
6citation items
$3,640current penalties
Nov 8, 2021last inspection

OSHA has inspected Construction Implements Depot, Inc. 2 times in North Carolina since 2006.

The latest one began on Nov 8, 2021 after a complaint, in Denton.

Those inspections ended with 6 citation items: 3 serious and 3 other-than-serious.

Penalties were first proposed at $5,600 and now stand at $3,640, 35% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 3 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Construction Implements Depot, Inc. averages $3,640 (1 cited inspection).

Construction Implements Depot, Inc. also files yearly injury logs with OSHA, summarized below.

Construction Implements Depot, Inc.: OSHA citation items per year, 2006 to 2021
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Construction Implements Depot, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345628523 OPENED NOV 8, 2021Closed

Complaint · Partial · Health · 210 employees at the site · Closed Feb 16, 2022

1248 N Main St, Denton, NC 27239 · Farm Machinery and Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$3,500$2,275Jan 21, 2022Final
Citation 1, item 2a
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$2,100$1,365Jan 21, 2022Final
Citation 1, item 2b
29 CFR 1910.1200(h)(2)(i) · Hazard communication
Serious$0$0Jan 21, 2022Final
Citation 2, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jan 21, 2022Final
Citation 2, item 2
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0Jan 21, 2022Final
Citation 2, item 3
29 CFR 1910.134(k)(3) · Respiratory protection
Other-than-serious$0$0Jan 21, 2022Final

Inspection 309512218 OPENED JAN 23, 2006Closed

Complaint · Partial · Health · 12 employees at the site · Closed Feb 10, 2006

1248 N. Main Street, Denton, NC 27239 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Denton site logged 14 recordable injuries or illnesses among about 220 workers: 6.3 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 53 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Construction Implements Depot
Denton · 2023
220 1456.32.7
Construction Implements Depot, Inc
Denton · 2019
140 835.42.7

Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.1200(h)(2)(i)

(i) The requirements of this section;

29 CFR 1910.134 · Respiratory protection

Other all other miscellaneous fabricated metal product manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.