Consumers Cooperative Society has 3 OSHA inspections on record in Iowa, the first in 2012.
OSHA's last visit started on May 20, 2025 after a complaint, in Coralville.
Across those inspections OSHA issued 24 citation items: 20 serious and 4 other-than-serious.
OSHA proposed $48,064 in penalties. After settlements and reviews the total is $42,707, down 11%.
Most often, OSHA cited 1910.132, personal protective equipment, general requirements (5 items).
For context, across all retail employers the median penalty per cited inspection since 2015 is $2,140. Consumers Cooperative Society averages $7,104 over 2 cited inspections in that time.
1 inspection on this page followed a fatal incident.
Inspection 345717870 OPENED JAN 10, 2022Closed
Referral · Partial · Safety · 11 employees at the site · Closed May 13, 2022
2321 Mahaffey Bridge Road, North Liberty, IA 52317 · Fuel Dealers · OSHA's record · Phone and website on Google Maps
Incident on Dec 30, 2021: Employee is burned in explosion trying to light pilot light
At 3:30 p.m. on December 30, 2021, an employee refilled a 500-gallon propane storage tank with with 415 gallons of LP-Gas. The employer was unable to determined if a leak check was performed after the fill. The employee entered the garage to light the pilot light but could not get it to ignite. The employee called a coworker (Service Manager) who instructed the employee to remove the drip cap and purge the line for a couple of minutes. The employee did as he was instructed, but he was located inside a building that had no ventilation where the purged gas was released. After the first attempt to ignite the the pilot light and after it would not light, the employee purged the line a second time letting the gas flow for approximately 2 more minutes. The employee next used a small handheld propane torch in an attempt to get the pilot light lit. As soon as he hit the igniter, a large explosion occurred. The two west and south walls were displaced from the structure under the roof and the two metal garage doors were blown approximately 70 feet away to the edge of the highway. The employee was buried under sheetrock near the furnace but was able to self-extricate himself and call for help. The employee incurred second degree burns to his hands and face and was transported by ambulance to the hospital, where he was transferred and admitted to a burn unit.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 29 CFR 88.4 - CODE OF IOWA (2021) |
Serious | $4,096 | $4,096 | Apr 8, 2022 | Final |
| Citation 1, item 2a |
Other-than-serious | $4,096 | $4,096 | Apr 8, 2022 | Final |
| Citation 1, item 2b |
Other-than-serious | $0 | $0 | Apr 8, 2022 | Final |
| Citation 2, item 1 |
Other-than-serious | $329 | $329 | Apr 8, 2022 | Final |
| Citation 2, item 2 |
Other-than-serious | $329 | $329 | Apr 8, 2022 | Final |
Inspection 316612613 OPENED JUL 10, 2012Closed
Accident · Partial · Safety · 35 employees at the site · Closed Dec 5, 2012
3500 2nd Street, Coralville, IA 52241 · Farm Supplies Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
Incident on Jul 9, 2012 (fatal): Worker is electrocuted while working on bin sweep auger
On July 9, 2012, Employee #1, an 18-year-old male with Consumers Cooperative Soc iety, had been cleaning out a grain bin with a worker at a Frytown location. In the morning, Employee #1 and a coworker completed the assembly of the sweep auge r, then stopped and went to lunch. After lunch, Employee #1 returned to grain bi n to work. Employee #1 had been working on platform outside hatch door on side o f bin. Platform was approximately 11. 4-feet above the ground. Employee #1 used a fiberglass extension ladder to reach bin mounted ladder to access work platfor m. Ladder was still in proper position when the coworker found Employee #1 on th e ground and unresponsive. Concern was raised about stray voltage or energized m etal in the incident area. A qualified electrician was contacted and responded t o the scene. Employee #1 had plugged in a remote control switch box to run the s weep auger motor. The wiring for the remote control switch box was through a por table relay panel box that had been dropped into the bin. The relay panel box co ntained a relay and had three cables running from it. One cable was a plug that went to a receptacle on the exterior of the bin above the hatch door to provide power. There were two other cables coming from the relay panel box, one to the r emote control switch box and one with a female connector for sweep auger motor t o plug in to. All wiring for the relay panel box and attached items were reviewe d by a qualified electrician. The plug to the exterior receptacle was a 20A 120/ 208 volt 3-phase-Y and the receptacle was rated for 20A 250V/10A 600 volt. The w iring to the receptacle was 480 volt. The plug had a ground prong which was supp osed to have an offset tang which was supposed to prevent improper insertion in the receptacle. The ground prong and the tang on the plug were even allowing ins ertion of the ground in any position. The plug was observed to have been inserte d 90 degrees turn from correct. The ground was inserted into a live wired slot c reating an energized connection at the remote control switch box. The remote con trol switch box had a metal collar and metal reducer fitting on the top exterior of the remote control switch box that registered 280 volt. The reducer fitting touched the grounding collar which was in contact with the ground screw/plat on the inside of the remote control switch box. The metal reducer fitting was a plu mbing fitting, not an electrical fitting, no UL rating on the fitting. Approxima tely forty minutes after returning from lunch, around 1:00 p.m. the coworker wen t out to check on Employee #1. Employee #1 was found unresponsive, laying face u p with his back flat on the ground in the vicinity of the grain bin. The coworke r summoned Emergency Medical Services, returned to building for help and to find an AED. The coworker sent another coworker out to stay with Employee #1 and sta rt chest compressions. Four trained coworkers responded with the AED while one c oworker remained on the phone with 911. Dispatch notified and dispatched first r esponders, ambulance and sheriff's office to scene. The coworkers performed CPR, connected AED and followed AED directions. Upon arrival of First Responders and Ambulance they assumed CPR and care for Employee #1. Sheriff's Deputy arrived o n scene. Employee #1 was transported to hospital. Employee #1 was declared decea sed at the hospital. Employee #1 presented with electric burns on hand and thora cic injuries either of which could be fatal. Employee #1 was delivered to county medical examiner for autopsy and to determine cause of death. The Medical Exami ner report stated cause of death as blunt force injuries of the chest after elec trocution. All wiring in the receptacle, the plug and the panel box were checked for burns or scorching, none was observed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Serious | $1,250 | $1,250 | Sep 14, 2012 | Closed |
| Citation 1, item 2 |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
| Citation 1, item 3a |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
| Citation 1, item 3b |
Serious | $0 | $0 | Sep 14, 2012 | Closed |
| Citation 1, item 4 |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
| Citation 1, item 5 |
Serious | $1,250 | $1,250 | Sep 14, 2012 | Closed |
| Citation 1, item 6 |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
| Citation 1, item 7 |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
| Citation 1, item 8 |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
| Citation 1, item 9 |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
| Citation 1, item 10 |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
| Citation 1, item 11 |
Serious | $3,500 | $3,500 | Sep 14, 2012 | Closed |
| Citation 1, item 12 |
Serious | $2,500 | $2,500 | Sep 14, 2012 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.