OSHA SearchOSHA records by employer

Copperstate Cabinet Company: OSHA inspections and violations

Phoenix, Arizona · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

10inspections
60citation items
$4,970current penalties
Jan 8, 2016last inspection

Since 1983, OSHA inspectors have visited Copperstate Cabinet Company in Arizona 10 times.

The most recent inspection opened on Jan 8, 2016 as a planned inspection, in Phoenix.

In all, OSHA issued 60 citation items: 20 serious and 40 other-than-serious.

The proposed penalties came to $7,345; today they stand at $4,970, 32% less.

The rule cited most here is 1910.213 (woodworking machinery), 14 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Copperstate Cabinet Company averages $750 across 1 cited inspection.

Copperstate Cabinet Company: OSHA citation items per year, 1983 to 2016
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

86employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Copperstate Cabinet Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341169951 OPENED JAN 8, 2016Closed

Planned · Complete · Safety · 4 employees at the site · Closed May 10, 2016

1932 W North Ln, Phoenix, AZ 85021 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$750$750Mar 28, 2016Final

Inspection 309115913 OPENED MAY 13, 2005Closed

Referral · Partial · Health · 16 employees at the site · Closed Sep 18, 2006

1932 West North Lane, Phoenix, AZ 85021 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$750$500Aug 3, 2005Closed
Citation 1, item 1b
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$0$0Aug 3, 2005Closed
Citation 1, item 1c
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$0$0Aug 3, 2005Closed
Citation 1, item 1d
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Aug 3, 2005Closed
Citation 1, item 1e
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Aug 3, 2005Closed
Citation 1, item 2a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$750$500Aug 3, 2005Closed
Citation 1, item 2b
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$0$0Aug 3, 2005Closed
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Aug 3, 2005Closed

Inspection 309070001 OPENED MAY 3, 2005Closed

Planned · Complete · Safety · 16 employees at the site · Closed Jul 7, 2006

1932 West North Lane, Phoenix, AZ 85021 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.243(b)(1) · Guarding of portable powered tools
Serious$750$375Jun 6, 2005Closed
Citation 1, item 2
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$750$375Jun 6, 2005Closed
Citation 1, item 3a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$750$375Jun 6, 2005Closed
Citation 1, item 3b
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Jun 6, 2005Closed
Citation 1, item 4
29 CFR 1910.213(p)(4) · Woodworking machinery
Serious$750$375Jun 6, 2005Closed
Citation 1, item 5a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$750$375Jun 6, 2005Closed
Citation 1, item 5b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 6, 2005Closed
Citation 2, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 3
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 4
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 5
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 6
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 7
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 8
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 9
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 10
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 11
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 12
29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 13
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 14
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 15
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 16
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Jun 6, 2005Closed
Citation 2, item 17
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jun 6, 2005Closed

Inspection 115610974 OPENED JUN 9, 1994Closed

Follow-up · Partial · Health · 22 employees at the site · Closed Jun 13, 1994

1932 West North Lane, Phoenix, AZ 85021 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 115610842 OPENED APR 27, 1994Closed

Planned · Complete · Health · 22 employees at the site · Closed Jun 16, 1994

1932 West North Lane, Phoenix, AZ 85021 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 230403 A
Serious$300$300May 24, 1994Closed
Citation 1, item 2
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$525$525May 24, 1994Closed
Citation 2, item 1
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0May 24, 1994Closed
Citation 2, item 2
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0May 24, 1994Closed
Citation 2, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0May 24, 1994Closed
Citation 2, item 4
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0May 24, 1994Closed
Citation 2, item 5
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0May 24, 1994Closed
Citation 2, item 6
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0May 24, 1994Closed

Inspection 108168527 OPENED MAR 20, 1990Closed

Follow-up · Partial · Safety · 20 employees at the site · Closed Mar 23, 1990

1932 West North Lane, Phoenix, AZ 85021 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108156779 OPENED JAN 3, 1990Closed

Planned · Complete · Safety · 21 employees at the site · Closed Mar 23, 1990

1932 West North Lane, Phoenix, AZ 85021 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 230403 A
Serious$280$280Jan 30, 1990Closed
Citation 2, item 1
29 CFR 1910.37(q)(6) · Exit routes
Other-than-serious$0$0Jan 30, 1990Closed
Citation 2, item 2
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Jan 30, 1990Closed
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 30, 1990Closed
Citation 2, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 30, 1990Closed
Citation 2, item 5
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Jan 30, 1990Closed
Citation 2, item 6
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jan 30, 1990Closed

Inspection 2575157 OPENED FEB 2, 1987Closed

Planned · Complete · Safety · 32 employees at the site · Closed Mar 11, 1987

1932 W. North Lane, Phoenix, AZ 85021 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Feb 13, 1987Closed
Citation 1, item 2
29 CFR 1910.213(p)(4) · Woodworking machinery
Other-than-serious$0$0Feb 13, 1987Closed
2 older inspections

Inspection 218044808 OPENED DEC 19, 1983Closed

Follow-up · Partial · Safety · 26 employees at the site · Closed Dec 21, 1983

1932 W North Lane, Phoenix, AZ 85021 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 218044519 OPENED NOV 9, 1983Closed

Planned · Complete · Safety · 26 employees at the site · Closed Dec 21, 1983

1932 W North Lane, Phoenix, AZ 85021 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$240$240Nov 18, 1983Closed
Citation 1, item 2
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Nov 18, 1983Closed
Citation 2, item 1
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$0$0Nov 18, 1983Closed
Citation 2, item 3
29 CFR 1910.213(p)(4) · Woodworking machinery
Other-than-serious$0$0Nov 18, 1983Closed
Citation 2, item 4
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Nov 18, 1983Closed
Citation 2, item 5
29 CFR 1910.242(a) · Hand and power tools
Other-than-serious$0$0Nov 18, 1983Closed
Citation 2, item 6
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Nov 18, 1983Closed
Citation 2, item 7
29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods
Other-than-serious$0$0Nov 18, 1983Closed
Citation 2, item 8
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Nov 18, 1983Closed
Citation 2, item 9
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Nov 18, 1983Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.106(e)(9)(iii)

(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

Other wood kitchen cabinet and countertop manufacturing employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.