OSHA SearchOSHA records by employer

Core Products International, Inc.: OSHA inspections and violations

Chetek, Wisconsin · Surgical Appliance and Supplies Manufacturing · NAICS 339113

4inspections
19citation items
$69,709current penalties
Sep 19, 2022last inspection

Core Products International, Inc. has 4 OSHA inspections on record in Wisconsin, the first in 2012.

OSHA's last visit started on Sep 19, 2022 as a planned inspection, in Chetek.

Across those inspections OSHA issued 19 citation items: 13 serious, 4 repeat and 2 other-than-serious.

OSHA proposed $106,936 in penalties. After settlements and reviews the total is $69,709, down 35%.

Most often, OSHA cited 1910.147, lockout/tagout (7 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Core Products International, Inc. averages $23,236 over 3 cited inspections in that time.

Core Products International, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Core Products International, Inc.: OSHA citation items per year, 2012 to 2022
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

218employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Core Products International, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346233133 OPENED SEP 19, 2022Closed

Planned · Complete · Safety · 70 employees at the site · Closed Mar 30, 2023

1505 Parker Drive, Chetek, WI 54728 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$5,635$3,381Feb 10, 2023Final

Inspection 344534490 OPENED DEC 26, 2019Closed

Planned · Partial · Safety · 83 employees at the site · Closed Jun 9, 2021

1505 Parker Drive, Chetek, WI 54728 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$5,725$4,007May 27, 2020Final
Citation 1, item 2a
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$7,634$5,343May 27, 2020Final
Citation 1, item 2b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 27, 2020Final
Citation 1, item 3
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$5,725$4,007May 27, 2020Final
Citation 1, item 4
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$5,725$4,007May 27, 2020Final
Citation 2, item 1a
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Repeat$26,718$16,030May 27, 2020Final
Citation 2, item 1b
29 CFR 1910.147(d)(3) · Lockout/tagout
Repeat$0$0May 27, 2020Final
Citation 2, item 1c
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Repeat$0$0May 27, 2020Final
Citation 2, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Repeat$19,085$11,451May 27, 2020Final

Inspection 343788501 OPENED FEB 14, 2019Closed

Referral · Partial · Safety · 77 employees at the site · Closed Oct 7, 2019

1505 Parker Drive, Chetek, WI 54728 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Feb 5, 2019: Employee amputates finger while operating strip cutter machi

At 1:00 p.m. on February 5, 2019, Employee #1 was operating a 4-inch, TRC brand, strip cutter machine to cut a 1 inch wide hook and loop (Velcro) material to length. While running the TRC strip cutter machine, Employee #1 reached into the out-feed side of the machine while she pressed a manual cut button. A part of the employee's finger was immediately amputated when the machine performed the cut stroke. The employee was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$11,934$8,354May 6, 2019Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$0$0May 6, 2019Final
Citation 1, item 1c
29 CFR 1910.147(d)(3) · Lockout/tagout
Serious$0$0May 6, 2019Final
Citation 1, item 1d
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0May 6, 2019Final
Citation 1, item 2a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$11,934$8,354May 6, 2019Final
Citation 1, item 2b
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$0$0May 6, 2019Final
Citation 1, item 3
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$5,115$3,580May 6, 2019Final
Citation 2, item 1
29 CFR 1904.32(b)(2)(ii) · Yearly injury summary
Other-than-serious$1,706$1,195May 6, 2019Final
Citation 2, item 3
29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens
Other-than-serious$0$0May 6, 2019Final

Inspection 331913335 OPENED FEB 13, 2012Closed

Complaint · Partial · Health · 60 employees at the site · Closed Mar 21, 2012

1505 Parker Drive, Chetek, WI 54728 · Surgical Appliance and Supplies Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Chetek site logged 0 recordable injuries or illnesses among about 54 workers: 0.0 per 100 full-time workers, against a median of 1.1 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Chetek Core Products
Chetek · 2025
54 000.01.1

Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 5, 2019, Chetek: Amputation · amputations · fingertip(s)

On February 5, 2019, an employee was operating a cutter machine to cut hooks when a hook became jammed inside the cutter. She stopped the machine on the control panel and attempted to remove the jammed hook. As she was unjamming the machine, the control panel was reactivated and the cutting blade contacted her finger, resulting in a fingertip amputation.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(b)(2)(ii)

(ii) Enter the calendar year covered, the company's name, establishment name, establishment address, annual average number of employees covered by the OSHA 300 Log, and the total hours worked by all employees covered by the OSHA 300 Log.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(i)

(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other surgical appliance and supplies manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.