OSHA SearchOSHA records by employer

Cortec Corporation: OSHA inspections and violations

Spooner, Wisconsin · All Other Miscellaneous Chemical Product and Preparation Manufacturing · NAICS 325998

3inspections
41citation items
$271,905current penalties
Jul 23, 2024last inspection

Cortec Corporation has 3 OSHA inspections on record in Wisconsin, the first in 2008.

OSHA's last visit started on Jul 23, 2024 after a complaint, in Spooner.

Across those inspections OSHA issued 41 citation items: 30 serious, 9 willful and 2 other-than-serious.

OSHA proposed $460,757 in penalties. After settlements and reviews the total is $271,905, down 41%.

Most often, OSHA cited 1910.119, process safety management (22 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Cortec Corporation averages $12,342 over 1 cited inspection in that time.

Cortec Corporation: OSHA citation items per year, 2008 to 2024
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Cortec Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347636599 OPENED JUL 23, 2024Closed

Complaint · Partial · Health · 7 employees at the site · Closed Dec 27, 2024

1300 South River Street, Spooner, WI 54801 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$8,816$6,171Nov 22, 2024Final
Citation 1, item 1b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Nov 22, 2024Final
Citation 1, item 2
29 CFR 1910.1200(h)(3)(ii) · Hazard communication
Serious$8,816$6,171Nov 22, 2024Final
Citation 2, item 1
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$0$0Nov 22, 2024Final

Inspection 339246340 OPENED JUL 31, 2013Closed

Planned · Partial · Health · 7 employees at the site · Closed Jan 5, 2015

1300 South River St., Spooner, WI 54801 · All Other Support Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$3,825$1,915Nov 26, 2013Final
Citation 1, item 1b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Nov 26, 2013Final
Citation 1, item 2
29 CFR 1910.119(d)(3)(i) · Process safety management
Serious$2,295$1,147Nov 26, 2013Final
Citation 1, item 3
29 CFR 1910.119(f)(3) · Process safety management
Serious$2,295$1,147Nov 26, 2013Final
Citation 1, item 4
29 CFR 1910.119(g)(3) · Process safety management
Serious$2,295$1,147Nov 26, 2013Final
Citation 1, item 5a
29 CFR 1910.119(h)(2)(ii) · Process safety management
Serious$2,295$1,147Nov 26, 2013Final
Citation 1, item 5b
29 CFR 1910.119(h)(2)(iii) · Process safety management
Serious$0$0Nov 26, 2013Final
Citation 1, item 5c
29 CFR 1910.119(h)(2)(v) · Process safety management
Serious$0$0Nov 26, 2013Final
Citation 1, item 5d
29 CFR 1910.119(h)(2)(vi) · Process safety management
Serious$0$0Nov 26, 2013Final
Citation 1, item 6a
29 CFR 1910.119(j)(4)(i) · Process safety management
Serious$3,060$1,530Nov 26, 2013Final
Citation 1, item 6b
29 CFR 1910.119(j)(2) · Process safety management
Serious$0$0Nov 26, 2013Final
Citation 1, item 7
29 CFR 1910.119(o)(4) · Process safety management
Serious$3,060$1,530Nov 26, 2013Final

Inspection 307044776 OPENED MAR 18, 2008Closed

Referral · Complete · Safety · 7 employees at the site · Closed Dec 10, 2010

1300 South River St., Spooner, WI 54801 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Mar 18, 2008: Two employees are injured in chemical plant explosion

At approximately 8:53 a.m. on March 18, 2008, Employee #1 and #2 were working on the production line of a manufacturing process. The facility manufactured aeros ol cans that were partially filled with various chemical products. The cans were pressurized with propellants that included carbon dioxide, Freon-134A, and two highly flammable propellants, A-70 (propane and isobutane), and A-31 (isobutane) , which both were maintained on the facility and in quantities that were in exce ss of 10,000 pounds, thus covered by the Process Safety Management standard. The propellants were injected into the cans via infeed lines from the propellant ta nks located on an adjacent tank farm. Following the injection of the propellant, a conveyor system moved the cans through two openings in a common wall of a gas house. Employees needed to begin a new aerosol product run, which required switc hing over the propellants from Freon-134A to A-70. Employee #1 and a coworker pu rged the A-70 return propellant line inside the gashouse for an extended period (at least 20 minutes) due to a vapor lock. This extended purging process was a s omewhat common practice when significant changes in ambient temperatures occurre d during the winter months. Because of the extended purging, the A-70 propellant leaked into the production area from the gashouse via the two conveyor openings . An electrical forklift of a Class 1 Division I and E rating, which was not sui table for such a flammable environment, was in the building at the time of the g as leak. Employee #1 attempted to relocate the forklift when the A-70 propellant gas leak within the building ignited and caused the building to explode. Employ ee #1 and #2 suffered critical injuries from the explosion. Employee #1 sustaine d third degree burns, whereas Employee #2 sustained third degree burns and unspe cified broken bones after being trapped underneath the collapsed structure. Both employees were originally transported to a local hospital for initial treatment . Upon receiving this treatment, they were reassessed and transferred to the bur n centers of different medical centers in different locations where they underwe nt medical care and were hospitalized. The investigation revealed that the gasho use contained a ventilation system, which was not operational and had blocked in take exhaust ventilation vents, and an alarm system that had been turned off, wh ich was connected to an LEL sensor in the gashouse, either of which would have l ikely prevented the explosion.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$4,000$4,000Sep 16, 2008Closed
Citation 1, item 1b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Sep 16, 2008Closed
Citation 1, item 2
29 CFR 1910.106(e)(2)(iib)(2) · Flammable liquids
Serious$4,000$4,000Sep 16, 2008Closed
Citation 1, item 3
29 CFR 1910.119(g)(1)(i) · Process safety management
Serious$5,600$5,600Sep 16, 2008Closed
Citation 1, item 4
29 CFR 1910.119(j)(6)(iii) · Process safety management
Serious$4,000$4,000Sep 16, 2008Closed
Citation 1, item 5
29 CFR 1910.119(m)(1) · Process safety management
Serious$5,600$5,600Sep 16, 2008Closed
Citation 1, item 6a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$4,000$4,000Sep 16, 2008Closed
Citation 1, item 6b
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$0$0Sep 16, 2008Closed
Citation 1, item 6c
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$0$0Sep 16, 2008Closed
Citation 1, item 7
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$2,000$2,000Sep 16, 2008Closed
Citation 1, item 8a
29 CFR 1910.147(c)(4)(iib) · Lockout/tagout
Serious$5,600$5,600Sep 16, 2008Closed
Citation 1, item 8b
29 CFR 1910.147(c)(4)(iid) · Lockout/tagout
Serious$0$0Sep 16, 2008Closed
Citation 1, item 8c
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Sep 16, 2008Closed
Citation 1, item 9
29 CFR 1910.178(b)(12) · Forklifts and other powered industrial trucks
Serious$5,600$5,600Sep 16, 2008Closed
Citation 1, item 10
29 CFR 1910.307(c)(2)(i) · Hazardous (classified) locations
Serious$5,600$5,600Sep 16, 2008Closed
Citation 2, item 1a
29 CFR 1910.119(d)(2)(id) · Process safety management
Willful$63,000$34,000Sep 16, 2008Closed
Citation 2, item 1b
29 CFR 1910.119(d)(2)(ie) · Process safety management
Willful$0$0Sep 16, 2008Closed
Citation 2, item 2
29 CFR 1910.119(d)(3)(i) · Process safety management
Willful$63,000$34,000Sep 16, 2008Closed
Citation 2, item 3
29 CFR 1910.119(e)(3) · Process safety management
Willful$63,000$34,000Sep 16, 2008Closed
Citation 2, item 4
29 CFR 1910.119(f)(1) · Process safety management
Willful$63,000$34,000Sep 16, 2008Closed
Citation 2, item 5a
29 CFR 1910.119(j)(2) · Process safety management
Willful$63,000$34,000Sep 16, 2008Closed
Citation 2, item 5b
29 CFR 1910.119(j)(3) · Process safety management
Willful$0$0Sep 16, 2008Closed
Citation 2, item 5c
29 CFR 1910.119(j)(4)(i) · Process safety management
Willful$0$0Sep 16, 2008Closed
Citation 2, item 6
29 CFR 1910.119(l)(1) · Process safety management
Willful$63,000$34,000Sep 16, 2008Closed
Citation 3, item 1 Other-than-serious$0$0Sep 16, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(2)(iib)(2)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.119 · Process safety management

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.95 · Noise

Other all other miscellaneous chemical product and preparation manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.