OSHA SearchOSHA records by employer

Countertop & Kitchen Cabinets Inc.: OSHA inspections and violations

Syracuse, New York · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

1inspections
21citation items
$3,700current penalties
Oct 21, 2016last inspection

OSHA inspectors have visited Countertop & Kitchen Cabinets Inc. in New York one time.

It opened on Oct 21, 2016 as a planned inspection, in Syracuse.

In all, OSHA issued 21 citation items: 19 serious and 2 other-than-serious.

The proposed penalties came to $17,927; today they stand at $3,700, 79% less.

The rule cited most here is 1910.1052 (methylene chloride), 11 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Countertop & Kitchen Cabinets Inc. averages $3,700 across 1 cited inspection.

Countertop & Kitchen Cabinets Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Countertop & Kitchen Cabinets Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341862423 OPENED OCT 21, 2016Closed

Planned · Complete · Health · 6 employees at the site · Closed Sep 5, 2018

4073 New Court Ave., Syracuse, NY 13206 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$1,630$325Mar 22, 2017Final
Citation 1, item 2a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,173$435Mar 22, 2017Final
Citation 1, item 2b
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$0$0Mar 22, 2017Final
Citation 1, item 2c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Mar 22, 2017Final
Citation 1, item 3
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$1,630$325Mar 22, 2017Final
Citation 1, item 4a
29 CFR 1910.1052(c)(2) · Methylene chloride
Serious$2,716$550Mar 22, 2017Final
Citation 1, item 4b
29 CFR 1910.1052(f)(1) · Methylene chloride
Serious$0$0Mar 22, 2017Final
Citation 1, item 4c
29 CFR 1910.1052(g)(1)(i) · Methylene chloride
Serious$0$0Mar 22, 2017Final
Citation 1, item 4d
29 CFR 1910.1052(g)(2)(i) · Methylene chloride
Serious$0$0Mar 22, 2017Final
Citation 1, item 5a
29 CFR 1910.1052(d)(2) · Methylene chloride
Serious$2,716$595Mar 22, 2017Final
Citation 1, item 5b
29 CFR 1910.1052(l)(1) · Methylene chloride
Serious$0$0Mar 22, 2017Final
Citation 1, item 6a
29 CFR 1910.1052(h)(1) · Methylene chloride
Serious$2,716$595Mar 22, 2017Final
Citation 1, item 6b
29 CFR 1910.1052(i)(1) · Methylene chloride
Serious$0$0Mar 22, 2017Final
Citation 1, item 6c
29 CFR 1910.1052(i)(2) · Methylene chloride
Serious$0$0Mar 22, 2017Final
Citation 1, item 7a
29 CFR 1910.1052(e)(1) · Methylene chloride
Serious$2,716$550Mar 22, 2017Final
Citation 1, item 7b
29 CFR 1910.1052(j)(1)(i) · Methylene chloride
Serious$0$0Mar 22, 2017Final
Citation 1, item 8a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,630$325Mar 22, 2017Final
Citation 1, item 8b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Mar 22, 2017Final
Citation 1, item 8c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Mar 22, 2017Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Other-than-serious$0$0Mar 22, 2017Final
Citation 2, item 2
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Mar 22, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1052 · Methylene chloride

29 CFR 1910.1052(c)(2)

(2) Short-term exposure limit (STEL). The employer shall ensure that no employee is exposed to an airborne concentration of MC in excess of one hundred and twenty-five parts of MC per million parts of air (125 ppm) as determined over a sampling period of fifteen minutes.

29 CFR 1910.1052(d)(2)

(2) Initial determination. Each employer whose employees are exposed to MC shall perform initial exposure monitoring to determine each affected employee's exposure, except under the following conditions:

29 CFR 1910.1052(e)(1)

(e) Regulated areas. (1) The employer shall establish a regulated area wherever an employee's exposure to airborne concentrations of MC exceeds or can reasonably be expected to exceed either the 8-hour TWA PEL or the STEL.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.22 · Walking-working surfaces

Other wood kitchen cabinet and countertop manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.