OSHA SearchOSHA records by employer

Csi Eifs Division, Inc: OSHA inspections and violations

Dothan, Alabama · Drywall and Insulation Contractors · NAICS 238310

1inspections
4citation items
$1,020current penalties
Jan 7, 2015last inspection

OSHA inspectors have visited Csi Eifs Division, Inc in Alabama one time.

It opened on Jan 7, 2015 as part of a related case, in Dothan.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $1,020 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Csi Eifs Division, Inc averages $1,020 across 1 cited inspection.

Csi Eifs Division, Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

102employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Csi Eifs Division, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340166057 OPENED JAN 7, 2015Closed

Programmed related · Partial · Safety · 4 employees at the site · Closed Nov 28, 2018

4654 Montgomery Hwy, Dothan, AL 36303 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2)(ii) · Scaffolds, general requirements
Serious$1,020$1,020Feb 19, 2015Final
Citation 1, item 1b
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$0$0Feb 19, 2015Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 19, 2015Final
Citation 1, item 1d
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Feb 19, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)(ii)

(ii) Where scaffolds must be used in areas that the employer can demonstrate are so narrow that platforms and walkways cannot be at least 18 inches (46 cm) wide, such platforms and walkways shall be as wide as feasible, and employees on those platforms and walkways shall be protected from fall hazards by the use of guardrails and/or personal fall arrest systems.

29 CFR 1926.451(b)(5)(i)

(5)(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.