OSHA SearchOSHA records by employer

Cummins-Wagner Company, Inc.: OSHA inspections and violations

Annapolis Junction, Maryland · Industrial Machinery and Equipment Merchant Wholesalers · NAICS 423830

2inspections
11citation items
$1,650current penalties
Apr 23, 2024last inspection

Since 2024, OSHA inspectors have visited Cummins-Wagner Company, Inc. in Maryland 2 times.

The most recent inspection opened on Apr 23, 2024 on a referral, in Annapolis Junction.

In all, OSHA issued 11 citation items: 4 serious and 7 other-than-serious.

The proposed penalties came to $2,812; today they stand at $1,650, 41% less.

The rule cited most here is 1910.107 (spray painting and finishing), 3 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,422 penalty. Cummins-Wagner Company, Inc. averages $825 across 2 cited inspections.

Cummins-Wagner Company, Inc. also files yearly injury logs with OSHA, summarized below.

Cummins-Wagner Company, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

175employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Cummins-Wagner Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347432791 OPENED APR 23, 2024Closed

Referral · Partial · Health · 88 employees at the site · Closed Aug 29, 2024

10901 Pump House Road, Annapolis Junction, MD 20701 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Jun 12, 2024Final
Citation 1, item 2
29 CFR 1910.107(b)(10) · Spray painting and finishing
Other-than-serious$0$0Jun 12, 2024Final
Citation 1, item 3
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Jun 12, 2024Final
Citation 1, item 4
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Jun 12, 2024Final

Inspection 347399362 OPENED APR 9, 2024Closed

Planned · Complete · Safety · 88 employees at the site · Closed Jul 31, 2024

10901 Pump House Road, Annapolis Junction, MD 20701 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,125$570Jul 9, 2024Final
Citation 1, item 2a
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$937$635Jul 9, 2024Final
Citation 1, item 2b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Jul 9, 2024Final
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$750$445Jul 9, 2024Final
Citation 2, item 1
29 CFR 1910.178(g)(2) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jul 9, 2024Final
Citation 2, item 2
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Other-than-serious$0$0Jul 9, 2024Final
Citation 2, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 9, 2024Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Annapolis Junction site logged 5 recordable injuries or illnesses among about 359 workers: 1.7 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 12 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Cummins-Wagner
Annapolis Junction · 2025
359 531.71.8
Annapolis Junction site
Annapolis Junction · 2018
81 000.01.4

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other industrial machinery and equipment merchant wholesalers employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.