OSHA SearchOSHA records by employer

Custom Cabinets by Don Inc: OSHA inspections and violations

Clackamas, Oregon · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

10inspections
40citation items
$4,695current penalties
Sep 25, 2018last inspection

OSHA has inspected Custom Cabinets by Don Inc 10 times in Oregon since 1992.

The latest one began on Sep 25, 2018 after a complaint, in Clackamas.

Those inspections ended with 40 citation items: 21 serious and 19 other-than-serious.

Penalties were first proposed at $4,695 and still stand at $4,695.

Respiratory protection comes up most often in these citations: 5 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Custom Cabinets by Don Inc averages $600 (1 cited inspection).

Custom Cabinets by Don Inc: OSHA citation items per year, 1992 to 2018
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Custom Cabinets by Don Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343488052 OPENED SEP 25, 2018Closed

Complaint · Partial · Health · 16 employees at the site · Closed May 7, 2019

10400 Se Mather Rd, Clackamas, OR 97015 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-002-0107(3)(E)(B)-1
Serious$150$150Jan 8, 2019Final
Citation 1, item 2a
29 CFR OAR 437-002-0107(3)(G)(F)
Serious$150$150Jan 8, 2019Final
Citation 1, item 2b
29 CFR OAR 437-002-0107(3)(G)(D)-2
Serious$0$0Jan 8, 2019Final
Citation 1, item 3
29 CFR OAR 437-002-0107(4)(D)(A)-3
Serious$150$150Jan 8, 2019Final
Citation 1, item 4a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$150$150Jan 8, 2019Final
Citation 1, item 4b
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$0$0Jan 8, 2019Final

Inspection 312843915 OPENED APR 9, 2009Closed

Referral · Partial · Health · 20 employees at the site · Closed Dec 10, 2009

10400 Se Mather Rd, Clackamas, OR 97015 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0Jul 15, 2009Closed
Citation 1, item 2
29 CFR 1910.1200(h)(2)(i) · Hazard communication
Other-than-serious$0$0Jul 15, 2009Closed

Inspection 312843725 OPENED APR 6, 2009Closed

Planned · Complete · Safety · 15 employees at the site · Closed Sep 9, 2009

10400 Se Mather Rd, Clackamas, OR 97015 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.242(b) · Hand and power tools
Serious$450$450Apr 27, 2009Closed
Citation 1, item 2a
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$450$450Apr 27, 2009Closed
Citation 1, item 2b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Apr 27, 2009Closed
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$270$270Apr 27, 2009Closed
Citation 1, item 4
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Serious$270$270Apr 27, 2009Closed
Citation 2, item 5
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Apr 27, 2009Closed
Citation 2, item 6 Other-than-serious$200$200Apr 27, 2009Closed
Citation 2, item 7
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Apr 27, 2009Closed

Inspection 309280782 OPENED DEC 21, 2005Closed

Complaint · Partial · Health · 20 employees at the site · Closed Jun 20, 2006

10400 Se Mather Rd, Clackamas, OR 97015 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$270$270Mar 1, 2006Closed
Citation 1, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$270$270Mar 1, 2006Closed

Inspection 307094003 OPENED MAR 31, 2004Closed

Referral · Partial · Health · 20 employees at the site · Closed Nov 18, 2004

10400 Se Mather Rd, Clackamas, OR 97015 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$165$165Jun 29, 2004Closed
Citation 1, item 2a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$165$165Jun 29, 2004Closed
Citation 1, item 2b Serious$0$0Jun 29, 2004Closed
Citation 1, item 3a
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$165$165Jun 29, 2004Closed
Citation 1, item 3b
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$0$0Jun 29, 2004Closed
Citation 2, item 4 Other-than-serious$0$0Jun 29, 2004Closed
Citation 2, item 5
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Jun 29, 2004Closed
Citation 2, item 6
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Other-than-serious$0$0Jun 29, 2004Closed

Inspection 307092072 OPENED FEB 19, 2004Closed

Planned · Complete · Safety · 20 employees at the site · Closed Aug 27, 2004

10400 Se Mather Rd, Clackamas, OR 97015 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$270$270Mar 17, 2004Closed
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$450$450Mar 17, 2004Closed
Citation 1, item 3
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$300$300Mar 17, 2004Closed
Citation 2, item 4
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Mar 17, 2004Closed
Citation 2, item 5 Other-than-serious$0$0Mar 17, 2004Closed
Citation 2, item 6 Other-than-serious$0$0Mar 17, 2004Closed
Citation 2, item 7 Other-than-serious$0$0Mar 17, 2004Closed
Citation 2, item 8 Other-than-serious$100$100Mar 17, 2004Closed

Inspection 306636002 OPENED AUG 25, 2003Closed

Complaint · Partial · Safety · 22 employees at the site · Closed Feb 12, 2004

10400 Se Mather Rd, Clackamas, OR 97015 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$100$100Sep 30, 2003Closed
Citation 2, item 2 Other-than-serious$100$100Sep 30, 2003Closed

Inspection 304101447 OPENED JAN 2, 2001Closed

Complaint · Partial · Safety · 19 employees at the site · Closed May 10, 2001

10400 Se Mather Rd, Clackamas, OR 97015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$100$100Jan 16, 2001Closed
2 older inspections

Inspection 123774226 OPENED MAY 6, 1993Closed

Planned · Complete · Safety · 11 employees at the site · Closed Apr 21, 1994

10400 Se Mather Rd, Clackamas, OR 97015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0May 28, 1993Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0May 28, 1993Closed

Inspection 115741811 OPENED JAN 8, 1992Closed

Planned · Complete · Safety · 18 employees at the site · Closed Mar 16, 1992

10400 Se Mather Rd, Clackamas, OR 97015 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Feb 11, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.1200(h)(2)(i)

(i) The requirements of this section;

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7001

29 CFR 7010.7200

29 CFR 7010.7600

29 CFR 7010.7650

29 CFR 7020.1070

29 CFR 7400.470

Other wood kitchen cabinet and countertop manufacturing employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.