Inspection 349208801 OPENED OCT 8, 2026Open
607 Bantam Road, Bantam, CT 06750 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Bantam, Connecticut · Custom Architectural Woodwork and Millwork Manufacturing · NAICS 337212
OSHA has inspected Custom Millwork & Design Group Inc. 2 times in Connecticut since 2021.
The latest one began on Oct 8, 2026 after a complaint, in Bantam; the case is still open.
Those inspections ended with 7 citation items: 6 serious and 1 other-than-serious.
Penalties were first proposed at $11,271 and now stand at $5,636, 50% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 4 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Custom Millwork & Design Group Inc. averages $5,636 (1 cited inspection).
Custom Millwork & Design Group Inc. also files yearly injury logs with OSHA, summarized below.
Connecticut · latest 90 days of OSHA records
89employers cited
Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Connecticut
Checking a subcontractor, a client or your own company? Watch Custom Millwork & Design Group Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company607 Bantam Road, Bantam, CT 06750 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
607 Bantam Road, Bantam, CT 06750 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(c)(9)(i) · Spray painting and finishing |
Serious | $3,522 | $1,761 | Feb 15, 2022 | Final |
| Citation 1, item 2 29 CFR 1910.107(d)(12) · Spray painting and finishing |
Serious | $2,818 | $1,409 | Feb 15, 2022 | Final |
| Citation 1, item 3 29 CFR 1910.107(e)(2) · Spray painting and finishing |
Serious | $2,113 | $1,056 | Feb 15, 2022 | Final |
| Citation 1, item 4a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $2,818 | $1,409 | Feb 15, 2022 | Final |
| Citation 1, item 4b 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Feb 15, 2022 | Final |
| Citation 1, item 4c 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Feb 15, 2022 | Final |
| Citation 2, item 1 29 CFR 1910.134(k)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Feb 15, 2022 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Bantam site logged 0 recordable injuries or illnesses among about 54 workers: 0.0 per 100 full-time workers, against a median of 3.3 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Custom Millwork & Design Group, Inc. Bantam · 2024 | 54 | 0 | 0 | 0.0 | 3.3 |
Included with any plan: 3 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(c)(9)(i)
(9) Grounding. (i) All metal parts of spray booths, exhaust ducts, and piping systems conveying flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) or aerated solids shall be properly electrically grounded in an effective and permanent manner.
29 CFR 1910.107(d)(12)
(12) Drying spaces. Freshly sprayed articles shall be dried only in spaces provided with adequate ventilation to prevent the formation of explosive vapors. In the event adequate and reliable ventilation is not provided such drying spaces shall be considered a spraying area. See also paragraph (j) of this section.
29 CFR 1910.107(e)(2)
(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.
Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.