OSHA SearchOSHA records by employer

D-K Manufacturing Corp.: OSHA inspections and violations

Fulton, New York · Forging and Stamping · NAICS 332116

5inspections
40citation items
$15,482current penalties
Jun 24, 2015last inspection

OSHA has inspected D-K Manufacturing Corp. 5 times in New York since 2003.

The latest one began on Jun 24, 2015 as a planned inspection, in Fulton.

Those inspections ended with 40 citation items: 39 serious and 1 other-than-serious.

Penalties were first proposed at $27,050 and now stand at $15,482, 43% lower after settlements or reviews.

Mechanical power presses comes up most often in these citations: 10 items under 1910.217.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and D-K Manufacturing Corp. averages $7,680 (1 cited inspection).

D-K Manufacturing Corp.: OSHA citation items per year, 2003 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch D-K Manufacturing Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340732205 OPENED JUN 24, 2015Closed

Planned · Partial · Safety · 20 employees at the site · Closed Sep 8, 2017

551 West Third Street, Fulton, NY 13069 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(c) · General requirements
Serious$1,600$960Jul 30, 2015Final
Citation 1, item 2
29 CFR 1910.23(d)(1) · Guarding floor and wall openings and holes
Serious$1,200$720Jul 30, 2015Final
Citation 1, item 3
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$1,600$960Jul 30, 2015Final
Citation 1, item 4
29 CFR 1910.178(l)(2)(ii) · Forklifts and other powered industrial trucks
Serious$2,400$1,440Jul 30, 2015Final
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,400$1,440Jul 30, 2015Final
Citation 1, item 6a
29 CFR 1910.217(c)(2)(i)(a) · Mechanical power presses
Serious$2,000$1,200Jul 30, 2015Final
Citation 1, item 6b
29 CFR 1910.217(c)(2)(i)(d) · Mechanical power presses
Serious$0$0Jul 30, 2015Final
Citation 1, item 6c
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$0$0Jul 30, 2015Final
Citation 1, item 7
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$1,600$960Jul 30, 2015Final

Inspection 314352097 OPENED APR 29, 2011Closed

Follow-up · Partial · Safety · 20 employees at the site · Closed May 6, 2011

551 West Third Street, Fulton, NY 13069 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314348863 OPENED DEC 15, 2010Closed

Planned · Partial · Safety · 20 employees at the site · Closed Feb 28, 2012

551 West Third Street, Fulton, NY 13069 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.36(d)(1) · Exit route design
Serious$3,000$1,400Dec 29, 2010Final
Citation 1, item 1b
29 CFR 1910.36(h)(2) · Exit route design
Serious$0$0Dec 29, 2010Final
Citation 1, item 1c
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Serious$0$0Dec 29, 2010Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,000$1,400Dec 29, 2010Final
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$2,400$1,200Dec 29, 2010Final
Citation 1, item 3b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 29, 2010Final
Citation 1, item 3c
29 CFR 1910.219(g) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 29, 2010Final

Inspection 309384576 OPENED NOV 14, 2006Closed

Planned · Partial · Safety · 24 employees at the site · Closed Dec 26, 2006

551 West Third Street, Fulton, NY 13069 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$375$244Nov 21, 2006Closed
Citation 1, item 1b
29 CFR 1910.212(a)(5) · Machine guarding
Serious$0$0Nov 21, 2006Closed
Citation 1, item 2a
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$375$244Nov 21, 2006Closed
Citation 1, item 2b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Nov 21, 2006Closed
Citation 1, item 3
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$375$244Nov 21, 2006Closed
Citation 1, item 4
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$375$244Nov 21, 2006Closed

Inspection 306311663 OPENED SEP 17, 2003Closed

Planned · Partial · Safety · 25 employees at the site · Closed Sep 2, 2004

551 West Third Street, Fulton, NY 13069 · Forging and Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$375$244Sep 25, 2003Closed
Citation 1, item 2
29 CFR 1910.36(h)(3) · Exit route design
Serious$375$244Sep 25, 2003Closed
Citation 1, item 3a
29 CFR 1910.37(a)(3) · Exit routes
Serious$375$244Sep 25, 2003Closed
Citation 1, item 3b
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Sep 25, 2003Closed
Citation 1, item 4
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$375$244Sep 25, 2003Closed
Citation 1, item 5
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$225$146Sep 25, 2003Closed
Citation 1, item 6
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$225$146Sep 25, 2003Closed
Citation 1, item 7
29 CFR 1910.212(a)(1) · Machine guarding
Serious$300$195Sep 25, 2003Closed
Citation 1, item 8
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$375$244Sep 25, 2003Closed
Citation 1, item 9a
29 CFR 1910.217(b)(3)(i) · Mechanical power presses
Serious$375$244Sep 25, 2003Closed
Citation 1, item 9b
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$0$0Sep 25, 2003Closed
Citation 1, item 10a
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$375$244Sep 25, 2003Closed
Citation 1, item 10b
29 CFR 1910.217(b)(7)(va) · Mechanical power presses
Serious$0$0Sep 25, 2003Closed
Citation 1, item 11a
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$375$244Sep 25, 2003Closed
Citation 1, item 11b
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$0$0Sep 25, 2003Closed
Citation 1, item 12
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$375$244Sep 25, 2003Closed
Citation 1, item 13
29 CFR 1910.242(b) · Hand and power tools
Serious$225$146Sep 25, 2003Closed
Citation 2, item 1
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Sep 25, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(f)(2)(ii)

(ii) Containers when stored inside shall not be located near exits, stairways, or in areas normally used or intended for the safe exit of people.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

OSH Act Section 5 · General Duty Clause

Other forging and stamping employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.