D.L. George & Sons Construction Co: OSHA inspections and violations
Waynesboro, Pennsylvania · Water and Sewer Line and Related Structures Construction · NAICS 237110
10inspections
26citation items
$18,590current penalties
Jul 7, 2015last inspection
D.L. George & Sons Construction Co has 10 OSHA inspections on record in Pennsylvania, the first in 1992.
OSHA's last visit started on Jul 7, 2015 on a referral, in Waynesboro.
Across those inspections OSHA issued 26 citation items: 17 serious and 9 other-than-serious.
OSHA proposed $29,395 in penalties. After settlements and reviews the total is $18,590, down 37%.
Most often, OSHA cited 1926.651, excavations (4 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. D.L. George & Sons Construction Co averages $4,300 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
D.L. George & Sons Construction Co also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Pennsylvania · latest 90 days of OSHA records
268employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch D.L. George & Sons Construction Co and get notified the morning OSHA posts a new citation for it.
Incident on Aug 29, 1994 (fatal): Employee killed in front end loader accident
Employee #1 was traveling approximately 15 to 20 mph down a one mile hill on a p aved road in a 1985 Clark rubber-tired front end loader, model #55-C. He was hea ded to a site to load rock dust onto dump trucks. Approximately 50 feet from the entrance to the dust ponds, the front end loader engine failed, causing the pow er steering and brakes to fail. Employee #1 went through a roadway guardrail nea r the pond entrance and into a box culvert about 15 feet deep. Employee #1, who was not wearing his seat belt, was thrown out of the loader's cab and through th e windshield. He landed in the loader bucket. Employee #1 died of internal injur ies.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Waynesboro site logged 2 recordable injuries or illnesses among about 115 workers: 1.6 per 100 full-time workers, against a median of 0.0 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
D. L. George & Sons Construction Company
Waynesboro · 2020
115
2
0
1.6
0.0
Included with any plan: 1 more yearly log from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
29 CFR 1910.106(e)(6)(i)
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.