OSHA SearchOSHA records by employer

Danco Precision Inc.: OSHA inspections and violations

Phoenixville, Pennsylvania · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · NAICS 333514

3inspections
23citation items
$41,190current penalties
Feb 18, 2025last inspection

OSHA has inspected Danco Precision Inc. 3 times in Pennsylvania since 2012.

The latest one began on Feb 18, 2025 as a planned inspection, in Phoenixville.

Those inspections ended with 23 citation items: 13 serious and 10 other-than-serious.

Penalties were first proposed at $76,701 and now stand at $41,190, 46% lower after settlements or reviews.

Mechanical power presses comes up most often in these citations: 6 items under 1910.217.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Danco Precision Inc. averages $13,240 (1 cited inspection).

Danco Precision Inc. also files yearly injury logs with OSHA, summarized below.

Danco Precision Inc.: OSHA citation items per year, 2012 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

295employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Danco Precision Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348054065 OPENED FEB 18, 2025Closed

Planned · Complete · Safety · 38 employees at the site · Closed Jun 30, 2025

601 Wheatland St., Phoenixville, PA 19460 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$11,585$4,634Mar 12, 2025Final
Citation 1, item 2
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Other-than-serious$11,585$4,634Mar 12, 2025Final
Citation 1, item 3
29 CFR 1910.1200(h)(2) · Hazard communication
Other-than-serious$9,931$3,972Mar 12, 2025Final
Citation 2, item 1
29 CFR 1910.1200(f)(6)(i) · Hazard communication
Other-than-serious$0$0Mar 12, 2025Final
Citation 2, item 2a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Mar 12, 2025Final
Citation 2, item 2b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Other-than-serious$0$0Mar 12, 2025Final

Inspection 339825911 OPENED JUN 25, 2014Closed

Planned · Records only · Safety · 37 employees at the site · Closed Jul 2, 2014

601 Wheatland St., Phoenixville, PA 19460 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315819250 OPENED MAR 1, 2012Open

Planned · Complete · Safety · 26 employees at the site · Open

354 Walnut Street, Phoenixville, PA 19460 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(c) · General requirements
Serious$3,500$3,000Aug 9, 2012Open
Citation 1, item 2a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$3,500$3,000Aug 9, 2012Open
Citation 1, item 3a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,900$4,000Aug 9, 2012Open
Citation 1, item 3b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Aug 9, 2012Open
Citation 1, item 4b
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Aug 9, 2012Open
Citation 1, item 5a Serious$2,800$2,000Aug 9, 2012Open
Citation 1, item 5b Serious$0$0Aug 9, 2012Open
Citation 1, item 6
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,900$4,000Aug 9, 2012Open
Citation 1, item 8a
29 CFR 1910.217(c)(3)(iiif) · Mechanical power presses
Serious$4,900$3,000Aug 9, 2012Open
Citation 1, item 8b
29 CFR 1910.217(c)(3)(vii) · Mechanical power presses
Serious$0$0Aug 9, 2012Open
Citation 1, item 9
29 CFR 1910.217(d)(1)(ii) · Mechanical power presses
Serious$4,900$3,000Aug 9, 2012Open
Citation 1, item 11a
29 CFR 1910.217(d)(9)(i) · Mechanical power presses
Other-than-serious$3,500$1,000Aug 9, 2012Open
Citation 1, item 11b
29 CFR 1910.217(d)(9)(iv) · Mechanical power presses
Serious$0$0Aug 9, 2012Open
Citation 1, item 12a
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$4,900$2,000Aug 9, 2012Open
Citation 1, item 13a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,800$2,000Aug 9, 2012Open
Citation 1, item 13b
29 CFR 1910.1200(f)(5) · Hazard communication
Serious$0$0Aug 9, 2012Open
Citation 2, item 1
29 CFR 1904.32(a)(2) · Yearly injury summary
Other-than-serious$3,000$950Aug 9, 2012Open

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Phoenixville site logged 1 recordable injury or illness among about 40 workers: 2.2 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Danco Precision Inc
Phoenixville · 2023
40 102.22.7
Danco Precision
Phoenixville · 2021
40 204.52.5

Included with any plan: 2 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(2)

(2) Create an annual summary of injuries and illnesses recorded on the OSHA 300 Log;

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(f)(5)

(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.22 · General requirements

Other special die and tool, die set, jig, and fixture manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.