OSHA SearchOSHA records by employer

Davis Painting & Decorating Inc.: OSHA inspections and violations

Oshkosh, Wisconsin · Painting and Wall Covering Contractors · NAICS 238320

8inspections
15citation items
$6,600current penalties
Aug 23, 2023last inspection

OSHA has inspected Davis Painting & Decorating Inc. 8 times in Wisconsin since 1988.

The latest one began on Aug 23, 2023 as a planned inspection, in Oshkosh.

Those inspections ended with 15 citation items: 8 serious and 7 other-than-serious.

Penalties were first proposed at $12,374 and now stand at $6,600, 47% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Davis Painting & Decorating Inc. averages $5,534 (1 cited inspection).

Davis Painting & Decorating Inc.: OSHA citation items per year, 1988 to 2023
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

218employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Davis Painting & Decorating Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346929755 OPENED AUG 23, 2023Closed

Planned · Partial · Health · 6 employees at the site · Closed Aug 24, 2023

1401 Kentucky Street, Oshkosh, WI 54901 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341690162 OPENED AUG 11, 2016Closed

Complaint · Partial · Safety · 19 employees at the site · Closed Apr 25, 2017

1302 S Main Street, Oshkosh, WI 54902 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Other-than-serious$3,029$400Dec 22, 2016Final
Citation 1, item 2a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$2,423$2,423Dec 22, 2016Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Dec 22, 2016Final
Citation 1, item 2c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Dec 22, 2016Final
Citation 1, item 3
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$2,423$1,212Dec 22, 2016Final
Citation 1, item 4a
29 CFR 1910.1048(d)(2) · Formaldehyde
Other-than-serious$3,029$1,500Dec 22, 2016Final
Citation 1, item 4b Serious$0$0Dec 22, 2016Final
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Dec 22, 2016Final
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 22, 2016Final
Citation 2, item 3
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Dec 22, 2016Final

Inspection 309842623 OPENED JUN 27, 2008Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 27, 2008

600 12th St, Mosinee, WI 54455 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309842508 OPENED JUN 26, 2008Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 6, 2008

450 Josslyn Street, Oshkosh, WI 54901 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.151(d)(2) · Fire prevention
Serious$600$420Sep 8, 2008Closed

Inspection 304011166 OPENED OCT 15, 2001Closed

Unprogrammed other · Partial · Safety · 20 employees at the site · Closed Jan 2, 2002

Gateway Store, Appleton, WI 54914 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$375$262Nov 15, 2001Closed
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$375$262Nov 15, 2001Closed

Inspection 106507031 OPENED OCT 18, 1991Closed

Planned · Complete · Safety · 1 employee at the site · Closed Oct 28, 1991

500 Ann Street School Addition, Weyauwega, WI 54983 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 103049847 OPENED SEP 20, 1990Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Nov 14, 1990

Fox River Mills Housing, Appleton, WI 54915 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$120$120Oct 15, 1990Closed
Citation 2, item 1
29 CFR 1926.150(c)(1)(vi) · Fire protection
Other-than-serious$0$0Oct 15, 1990Closed

Inspection 102541596 OPENED SEP 6, 1988Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 14, 1988

Waupaca Place Hotel, Waupaca, WI 54981 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1048 · Formaldehyde

29 CFR 1910.1048(d)(2)

(2) Initial monitoring. The employer shall identify all employees who may be exposed at or above the action level or at or above the STEL and accurately determine the exposure of each employee so identified.

29 CFR 1910.1048(m)(1)(iii)

(iii) Employers shall include formaldehyde in the hazard communication program established to comply with the HCS (§ 1910.1200). Employers shall ensure that each employee has access to labels on containers of formaldehyde and to safety data sheets, and is trained in accordance with the requirements of HCS and paragraph (n) of this section.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1926.150 · Fire protection

29 CFR 1926.151 · Fire prevention

29 CFR 1926.202

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.59 · Hazard communication

Other painting and wall covering contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.