Dean Steel Buildings, Inc.: OSHA inspections and violations
Ft Myers, Florida · Prefabricated Metal Building and Component Manufacturing · NAICS 332311
12inspections
58citation items
$14,717current penalties
Dec 16, 2025last inspection
OSHA has inspected Dean Steel Buildings, Inc. 12 times in Florida since 1973.
The latest one began on Dec 16, 2025 on a referral, in Fort Myers.
Those inspections ended with 58 citation items: 23 serious and 35 other-than-serious.
Penalties were first proposed at $20,532 and now stand at $14,717, 28% lower after settlements or reviews.
Machine guarding comes up most often in these citations: 8 items under 1910.212.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Dean Steel Buildings, Inc. averages $3,931 (2 cited inspections).
Dean Steel Buildings, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Florida · latest 90 days of OSHA records
311employers cited
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Dean Steel Buildings, Inc. and get notified the morning OSHA posts a new citation for it.
Incident on Nov 23, 2018: Employee sustains amputation while operating hydraulic brake
At 11:32 a.m. on November 23, 2018, an employee was working for a firm that manufactured prefabricated metal buildings and components. He was operating a hydraulic brake. The brake had a jaw. As the jaw closed, it pinched the ring finger and little finger on one of his hands. He sustained the amputation of the tip of his ring finger and of his entire little finger. He was hospitalized. hospitalized.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Fort Myers site logged 7 recordable injuries or illnesses among about 43 workers: 17.4 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 2 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Dean Steel Buildings, Inc
Fort Myers · 2024
43
7
2
17.4
3.6
Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Nov 11, 2025, Fort Myers: Amputation · amputations involving bone loss · finger or thumb tip(s), nail(s)
An employee was working with a metal shear machine. The machine's blades engaged while the employee was handling sheet metal, and the last joint of the employee's middle fingertip was amputated.
Nov 23, 2018, Fort Myers: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.
An employee at Dean Steel Buildings, Inc., was operating a flashing machine to bend siding when the machine was activated via the foot pedal and pinched his right hand with the material he was bending. This resulted in a fourth finger amputation and a partial right middle fingertip amputation.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(iii) Emergency power cutoff. A clearly identified and easily accessible switch(es) or a circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.
29 CFR 1910.106(g)(9)
(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.