OSHA SearchOSHA records by employer

Delta Millworks, Inc.: OSHA inspections and violations

Austin, Texas · Sawmills · NAICS 321113

2inspections
24citation items
$16,600current penalties
Jul 20, 2026last inspection

Delta Millworks, Inc. has 2 OSHA inspections on record in Texas, the first in 2015.

OSHA's last visit started on Jul 20, 2026 on a referral, in Austin, and the case has not closed yet.

Across those inspections OSHA issued 24 citation items: 24 serious.

OSHA proposed $33,200 in penalties. After settlements and reviews the total is $16,600, down 50%.

Most often, OSHA cited 1910.305, electrical wiring methods (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Delta Millworks, Inc. averages $16,600 over 1 cited inspection in that time.

Delta Millworks, Inc. also files yearly injury logs with OSHA, summarized below.

Delta Millworks, Inc.: OSHA citation items per year, 2015 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Delta Millworks, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349062943 OPENED JUL 20, 2026Open

Referral · Partial · Safety · 76 employees at the site · Open

4701 East 5th Street, Austin, TX 78702 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 340911767 OPENED SEP 10, 2015Closed

Complaint · Complete · Safety · 25 employees at the site · Closed Apr 10, 2018

4701 E 5th Street, Austin, TX 78702 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,800$1,400Mar 3, 2016Final
Citation 1, item 2a
29 CFR 1910.22(a)(1) · General requirements
Serious$2,800$1,400Mar 3, 2016Final
Citation 1, item 2b
29 CFR 1910.22(a)(2) · General requirements
Serious$0$0Mar 3, 2016Final
Citation 1, item 3a
29 CFR 1910.37(a)(3) · Exit routes
Serious$1,200$600Mar 3, 2016Final
Citation 1, item 3b
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Mar 3, 2016Final
Citation 1, item 4
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,800$1,400Mar 3, 2016Final
Citation 1, item 5a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$1,200$600Mar 3, 2016Final
Citation 1, item 5b
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Mar 3, 2016Final
Citation 1, item 6
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,600$800Mar 3, 2016Final
Citation 1, item 7
29 CFR 1910.212(a)(5) · Machine guarding
Serious$1,600$800Mar 3, 2016Final
Citation 1, item 8
29 CFR 1910.213(i)(1) · Woodworking machinery
Serious$2,800$1,400Mar 3, 2016Final
Citation 1, item 9
29 CFR 1910.213(n)(1) · Woodworking machinery
Serious$1,600$800Mar 3, 2016Final
Citation 1, item 10a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$2,000$1,000Mar 3, 2016Final
Citation 1, item 10b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 3, 2016Final
Citation 1, item 11
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$1,600$800Mar 3, 2016Final
Citation 1, item 12a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,600$800Mar 3, 2016Final
Citation 1, item 12b
29 CFR 1910.303(c) · Electrical equipment, general requirements
Serious$0$0Mar 3, 2016Final
Citation 1, item 13a
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$2,400$1,200Mar 3, 2016Final
Citation 1, item 13b
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Mar 3, 2016Final
Citation 1, item 14a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,000$1,000Mar 3, 2016Final
Citation 1, item 14b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Mar 3, 2016Final
Citation 1, item 15
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$1,200$600Mar 3, 2016Final
Citation 1, item 16
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$2,800$1,400Mar 3, 2016Final
Citation 1, item 17
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,200$600Mar 3, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Austin site logged 4 recordable injuries or illnesses among about 73 workers: 5.1 per 100 full-time workers, against a median of 4.2 for its industry. Those cases cost 1 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Delta Millworks
Austin · 2025
73 415.14.2

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.37 · Exit routes

OSH Act Section 5 · General Duty Clause

Other sawmills employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.