OSHA SearchOSHA records by employer

Derouen Electrical Service, Inc.: OSHA inspections and violations

Avery Island, Louisiana · Other Services to Buildings and Dwellings · NAICS 561790

2inspections
5citation items
$5,670current penalties
Jul 24, 2018last inspection

Since 2006, OSHA inspectors have visited Derouen Electrical Service, Inc. in Louisiana 2 times.

The most recent inspection opened on Jul 24, 2018, in Carencro.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $12,374; today they stand at $5,670, 54% less.

The rule cited most here is 1910.333 (working near live electrical parts), 2 times.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,218 penalty. Derouen Electrical Service, Inc. averages $2,070 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Derouen Electrical Service, Inc.: OSHA citation items per year, 2006 to 2018
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Derouen Electrical Service, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343356945 OPENED JUL 24, 2018Closed

Programmed other · Partial · Safety · 11 employees at the site · Closed Jul 15, 2019

909 Pont De Mouton Rd., Carencro, LA 70520 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms
Serious$5,174$2,070Dec 14, 2018Final

Inspection 310244843 OPENED AUG 23, 2006Closed

Accident · Partial · Safety · 2 employees at the site · Closed Nov 2, 2007

Hwy 329, Avery Island, LA 70513 · Other Services to Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

Incident on Aug 22, 2006 (fatal): Employee is electrocuted while replacing ballast

On August 22, 2006, Employee #1, an electrician apprentice, was assigned to repl ace the ballast in a ceiling-mounted light fixture. While Employee #1 was changi ng the ballast from a ladder on a catwalk, he was electrocuted. Employee #1 fell to the main floor, just below the catwalk where he was working, and was killed. No one witnessed the accident.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,100$1,050Nov 22, 2006Final
Citation 1, item 2
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$2,100$1,050Nov 22, 2006Final
Citation 1, item 3
29 CFR 1910.333(c)(2) · Working near live electrical parts
Serious$1,500$750Nov 22, 2006Final
Citation 1, item 4
29 CFR 1910.335(a)(2)(i) · Safeguards for personnel protection
Serious$1,500$750Nov 22, 2006Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.332 · Training

29 CFR 1910.332(b)(1)

(b) Content of training—(1) Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by §§ 1910.331 through 1910.335 that pertain to their respective job assignments.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

29 CFR 1910.333(c)(2)

(2) Work on energized equipment. Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

Other other services to buildings and dwellings employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.