Dexter Fortson Associates, Inc.: OSHA inspections and violations

Coaling, Alabama · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
8citation items
$72,071current penalties
Jun 20, 2024last inspection

OSHA has inspected Dexter Fortson Associates, Inc. once in Alabama.

The inspection began on Jun 20, 2024 after a fatality or catastrophe, in Coaling.

That inspection ended with 8 citation items: 6 serious and 2 other-than-serious.

Penalties were first proposed at $84,789 and now stand at $72,071, 15% lower after settlements or reviews.

Electric power generation, transmission, and distribution comes up most often in these citations: 5 items under 1910.269.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Dexter Fortson Associates, Inc. averages $72,071 (1 cited inspection).

2 inspections on this page followed a fatal incident.

Dexter Fortson Associates, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

95employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Dexter Fortson Associates, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347564601 OPENED JUN 20, 2024Closed

Fatality or catastrophe · Partial · Safety · 40 employees at the site · Closed Jan 24, 2025

33.12927 N; 87.37874 W, Coaling, AL 35449 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 19, 2024 (fatal): Employee dies following electrocution

At 1:30 p.m. on June 19, 2024, Employee #1, a crew member working on power line connections in Coaling, Alabama, was performing electrical work on Utility Pole 2080. After making final connections to energize the circuit, Employee #1 elevated in a bucket truck to replace a broken cutout switch but came into contact with an energized power line. The laborer, who had been working alongside Employee #1, found him unresponsive in the bucket with burns on his face, arms, and other parts of his body. Emergency services were called, but Employee #1 was declared dead at the scene due to high-voltage electrocution.

Incident on Jun 19, 2024 (fatal): Employee is killed when electrocuted

At 1:30 p.m. on June 19, 2024, an employee was electrocuted while accomplishing maintenance on a 7.2kV distribution line. The employee was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.137(c)(2)(viii) · Electrical protective equipment
Serious$11,292$9,598Dec 17, 2024Final
Citation 1, item 2
OSH Act Section 5(a)(1) · General Duty Clause
Serious$11,292$9,598Dec 17, 2024Final
Citation 1, item 3
29 CFR 1910.269(a)(2)(iv) · Electric power generation, transmission, and distribution
Other-than-serious$11,292$9,598Dec 17, 2024Final
Citation 1, item 4
29 CFR 1910.269(c)(1)(ii) · Electric power generation, transmission, and distribution
Serious$11,292$9,598Dec 17, 2024Final
Citation 1, item 5
29 CFR 1910.269(j)(2)(iii) · Electric power generation, transmission, and distribution
Serious$11,292$9,598Dec 17, 2024Final
Citation 1, item 6
29 CFR 1910.269(l)(3)(iii) · Electric power generation, transmission, and distribution
Serious$11,292$9,598Dec 17, 2024Final
Citation 1, item 7
29 CFR 1910.269(m)(3)(ii) · Electric power generation, transmission, and distribution
Serious$16,131$13,711Dec 17, 2024Final
Citation 2, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$906$770Dec 17, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.137 · Electrical protective equipment

29 CFR 1910.137(c)(2)(viii)

(viii) Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(a)(2)(iv)

(iv) The employer shall determine, through regular supervision and through inspections conducted on at least an annual basis, that each employee is complying with the safety-related work practices required by this section.

OSH Act Section 5 · General Duty Clause

Other electrical contractors and other wiring installation contractors employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.