OSHA SearchOSHA records by employer

Dickie Equipment Co Inc: OSHA inspections and violations

Dodge Center, Minnesota · Industrial Machinery Manufacturing · NAICS 333298

10inspections
40citation items
$10,842current penalties
Sep 1, 2016last inspection

OSHA has inspected Dickie Equipment Co Inc 10 times in Minnesota since 1984.

The latest one began on Sep 1, 2016 on a referral, in Claremont.

Those inspections ended with 40 citation items: 23 serious and 17 other-than-serious.

Penalties were first proposed at $15,297 and now stand at $10,842, 29% lower after settlements or reviews.

Lead in general industry comes up most often in these citations: 7 items under 1910.1025.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Dickie Equipment Co Inc averages $375 (2 cited inspections).

Dickie Equipment Co Inc: OSHA citation items per year, 1984 to 2016
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

371employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Dickie Equipment Co Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341748887 OPENED SEP 1, 2016Closed

Referral · Partial · Health · 3 employees at the site · Closed Mar 7, 2017

114 Front Street, Claremont, MN 55924 · Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$500$100Oct 14, 2016Final
Citation 1, item 2
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$1,125$100Oct 14, 2016Final
Citation 1, item 3
29 CFR 1910.252(b)(4)(iv) · Welding fire safety
Serious$625$100Oct 14, 2016Final
Citation 1, item 4a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$1,125$100Oct 14, 2016Final
Citation 1, item 4b
29 CFR 1910.252(c)(1)(iii) · Welding fire safety
Serious$0$0Oct 14, 2016Final
Citation 2, item 1 Other-than-serious$250$100Oct 14, 2016Final

Inspection 341629731 OPENED JUL 18, 2016Closed

Planned · Complete · Safety · 3 employees at the site · Closed Oct 28, 2016

114 Front Street, Claremont, MN 55924 · Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$125$125Aug 17, 2016Final
Citation 1, item 2 Other-than-serious$125$125Aug 17, 2016Final

Inspection 316383991 OPENED FEB 24, 2012Closed

Complaint · Partial · Health · 4 employees at the site · Closed Apr 24, 2014

114 Front Street, Claremont, MN 55924 · Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$350$210May 1, 2012Final
Citation 1, item 2
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$875$525May 1, 2012Final
Citation 1, item 3
29 CFR 1910.1026(l)(1) · Hexavalent chromium
Serious$875$525May 1, 2012Final
Citation 1, item 4 Serious$1,050$630May 1, 2012Final
Citation 2, item 1 Other-than-serious$175$105May 1, 2012Final
Citation 2, item 2 Other-than-serious$0$0May 1, 2012Closed

Inspection 316384056 OPENED FEB 24, 2012Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Aug 27, 2012

114 Front Street, Claremont, MN 55924 · Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$525$525May 1, 2012Closed
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$525$525May 1, 2012Closed
Citation 1, item 3
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$525$525May 1, 2012Closed
Citation 1, item 4a
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Serious$700$700May 1, 2012Closed
Citation 1, item 4b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$0$0May 1, 2012Closed
Citation 1, item 5
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$875$875May 1, 2012Closed
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,225$1,225May 1, 2012Closed
Citation 1, item 7
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Serious$525$525May 1, 2012Closed
Citation 1, item 8
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$875$875May 1, 2012Closed
Citation 1, item 9 Serious$700$700May 1, 2012Closed
Citation 2, item 1
29 CFR 1910.23(a)(9) · Guarding floor and wall openings and holes
Other-than-serious$175$175May 1, 2012Closed
Citation 2, item 2
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$175$175May 1, 2012Closed
Citation 2, item 3
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$175$175May 1, 2012Closed
Citation 2, item 4
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$175$175May 1, 2012Closed
Citation 2, item 5 Other-than-serious$175$175May 1, 2012Closed

Inspection 2415545 OPENED MAY 20, 1986Closed

Follow-up · Partial · Health · 4 employees at the site · Closed Jun 11, 1986

East Hwy. 14, Dodge Center, MN 55927 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 2878437 OPENED MAY 21, 1985Closed

Referral · Partial · Health · 6 employees at the site · Closed Jul 29, 1986

East Highway 14, Dodge Center, MN 55927 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$400$400Jul 12, 1985Final
Citation 1, item 2
29 CFR 1910.1025(c)(1) · Lead in general industry
Serious$136$136Jul 12, 1985Final
Citation 1, item 3
29 CFR 1910.1025(j)(1)(i) · Lead in general industry
Serious$124$124Jul 12, 1985Final
Citation 2, item 1
29 CFR 1910.1025(d)(2) · Lead in general industry
Other-than-serious$0$0Jul 12, 1985Final
Citation 2, item 2
29 CFR 1910.1025(g)(1) · Lead in general industry
Other-than-serious$0$0Jul 12, 1985Final
Citation 2, item 3
29 CFR 1910.1025(i)(2) · Lead in general industry
Other-than-serious$0$0Jul 12, 1985Final
Citation 2, item 4
29 CFR 1910.1025(l)(1) · Lead in general industry
Other-than-serious$0$0Jul 12, 1985Final
Citation 2, item 5
29 CFR 1910.1025(m)(2) · Lead in general industry
Other-than-serious$0$0Jul 12, 1985Final

Inspection 2906329 OPENED MAY 21, 1985Closed

Follow-up · Partial · Safety · 6 employees at the site · Closed May 24, 1985

East Highway 14, Dodge Center, MN 55927 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 14910731 OPENED APR 8, 1985Closed

Follow-up · Partial · Safety · 11 employees at the site · Closed May 24, 1985

East Highway 14, Dodge Center, MN 55927 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

2 older inspections

Inspection 14892657 OPENED DEC 18, 1984Closed

Follow-up · Partial · Safety · 11 employees at the site · Closed May 24, 1985

East Highway 14, Dodge Center, MN 55927 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(2)(ii) · Respiratory protection
Other-than-serious$0$0Jan 3, 1985Closed
Citation 1, item 2
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Jan 3, 1985Closed

Inspection 14896559 OPENED OCT 31, 1984Closed

Complaint · Partial · Safety · 8 employees at the site · Closed May 24, 1985

E Hwy 14, Dodge Center, MN 55927 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.94(c)(2) · Ventilation
Serious$87$87Nov 19, 1984Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(c)(1)

(c) Permissible exposure limit (PEL). (1) The employer shall assure that no employee is exposed to lead at concentrations greater than fifty micrograms per cubic meter of air (50 µg/m 3) averaged over an 8-hour period.

29 CFR 1910.1025(d)(2)

(2) Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any exployee may be exposed to lead at or above the action level.

29 CFR 1910.1025(g)(1)

(g) Protective work clothing and equipment—(1) Provision and use. If an employee is exposed to lead above the PEL, without regard to the use of respirators or where the possibility of skin or eye irritation exists, the employer shall provide at no cost to the employee and assure that the employee uses appropriate protective work clothing and equipment such as, but not limited to:

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

29 CFR 5205.116

29 CFR 5205.1200

29 CFR 5205.660

29 CFR 5206.700

Other industrial machinery manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.