OSHA SearchOSHA records by employer

Dillon Construction Services Inc: OSHA inspections and violations

Columbia, South Carolina · Drywall and Insulation Contractors · NAICS 238310

25inspections
72citation items
$21,182current penalties
May 2, 2019last inspection

Dillon Construction Services Inc has 25 OSHA inspections on record in South Carolina, the first in 1990.

OSHA's last visit started on May 2, 2019 as a planned inspection, in Columbia.

Across those inspections OSHA issued 72 citation items: 60 serious and 12 other-than-serious.

OSHA proposed $30,750 in penalties. After settlements and reviews the total is $21,182, down 31%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (47 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Dillon Construction Services Inc averages $437 over 1 cited inspection in that time.

Dillon Construction Services Inc: OSHA citation items per year, 1990 to 2019
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

43employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Dillon Construction Services Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343988689 OPENED MAY 2, 2019Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 20, 2019

701 Whaley Street, Columbia, SC 29201 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$4,200$437Jun 12, 2019Final

Inspection 315185769 OPENED DEC 1, 2010Closed

Planned · Partial · Safety · 2 employees at the site · Closed Feb 7, 2011

1931 Sumter St, Columbia, SC 29201 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$100$100Jan 24, 2011Closed

Inspection 311514038 OPENED APR 15, 2008Closed

Planned · Complete · Safety · 15 employees at the site · Closed Apr 25, 2008

273 Meeting St, Charleston, SC 29401 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309803724 OPENED AUG 16, 2006Closed

Planned · Complete · Safety · 5 employees at the site · Closed Oct 13, 2006

3520 W Montague, North Charleston, SC 29405 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$250$250Sep 20, 2006Closed

Inspection 308233246 OPENED NOV 9, 2004Closed

Planned · Complete · Safety · 7 employees at the site · Closed Dec 30, 2004

2604 Ashley River Road, Charleston, SC 29407 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Dec 7, 2004Closed

Inspection 302450770 OPENED JAN 6, 2000Closed

Planned · Complete · Safety · 8 employees at the site · Closed Apr 19, 2000

100 Park Ridge Road, Columbia, SC 29210 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 5a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$500Feb 3, 2000Closed
Citation 3, item 5b
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Feb 3, 2000Closed
Citation 3, item 5c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 3, 2000Closed
Citation 3, item 5d
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Feb 3, 2000Closed

Inspection 302447339 OPENED DEC 7, 1999Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 14, 2000

Hwy 6, Lexington, SC 29072 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$200$200Feb 1, 2000Closed

Inspection 302447172 OPENED NOV 3, 1999Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 6, 1999

Trenholm Road Extension, Columbia, SC 29205 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(9) · Scaffolds, general requirements
Serious$0$0Dec 2, 1999Closed
Citation 1, item 2
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$0$0Dec 2, 1999Closed
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Dec 2, 1999Closed
17 older inspections

Inspection 301759981 OPENED JAN 14, 1999Closed

Planned · Partial · Safety · 5 employees at the site · Closed Feb 8, 1999

Calhoun St. At Rutledge Ave., Charleston, SC 29401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 4, item 1
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$0$0Feb 8, 1999Closed
Citation 4, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Feb 8, 1999Closed

Inspection 301757464 OPENED SEP 23, 1998Closed

Planned · Partial · Safety · 10 employees at the site · Closed Oct 21, 1998

Clemson Road, Columbia, SC 29223 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Oct 20, 1998Closed

Inspection 301759494 OPENED SEP 15, 1998Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jan 5, 2011

316 S. Beltline Blvd., Columbia, SC 29205 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$750$750Oct 15, 1998Closed
Citation 2, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$750$750Oct 15, 1998Closed
Citation 2, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$750$750Oct 15, 1998Closed
Citation 2, item 4
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$750$750Oct 15, 1998Closed
Citation 2, item 5a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,125$1,125Oct 15, 1998Closed
Citation 2, item 5b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Oct 15, 1998Closed

Inspection 301772232 OPENED AUG 5, 1998Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jan 5, 2011

Magnolia St., Orangeburg, SC 29115 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$250$250Aug 18, 1998Closed
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$250$250Aug 18, 1998Closed

Inspection 301764080 OPENED APR 28, 1998Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Jan 5, 2011

334 Calhoun Street, Charleston, SC 29401 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301754909 OPENED JAN 21, 1998Closed

Planned · Partial · Safety · 6 employees at the site · Closed Feb 24, 1998

450 Second Loop Rd., Florence, SC 29501 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$250$250Feb 11, 1998Closed
Citation 2, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$250$250Feb 11, 1998Closed
Citation 2, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$250$250Feb 11, 1998Closed
Citation 2, item 4
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$250$250Feb 11, 1998Closed

Inspection 301751509 OPENED AUG 21, 1997Closed

Planned · Partial · Safety · 3 employees at the site · Closed Mar 31, 1998

North Main Street, Summerville, SC 29483 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$625$625Sep 12, 1997Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$625$625Sep 12, 1997Final
Citation 1, item 3
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$375$375Sep 12, 1997Final
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$625$625Sep 12, 1997Final
Citation 1, item 5
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$625$625Sep 12, 1997Final
Citation 1, item 6a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$625$625Sep 12, 1997Final
Citation 1, item 6b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Sep 12, 1997Final

Inspection 126498864 OPENED JUN 25, 1996Closed

Planned · Partial · Safety · 6 employees at the site · Closed Feb 28, 1997

Park St. At Lady St., Columbia, SC 29201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 4, item 1
29 CFR 10012 A
Serious$1,250$1,250Jul 11, 1996Final
Citation 4, item 2
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$250$250Jul 11, 1996Final
Citation 4, item 3
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$250$250Jul 11, 1996Final
Citation 4, item 4
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$250$250Jul 11, 1996Final
Citation 4, item 5
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,250$660Jul 11, 1996Final

Inspection 126497205 OPENED MAR 26, 1996Closed

Planned · Partial · Safety · 15 employees at the site · Closed Sep 20, 1996

Greystone Blvd. At I-26, Columbia, SC 29210 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 10012 A
Serious$750$375Apr 12, 1996Final
Citation 3, item 2
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$750$375Apr 12, 1996Final
Citation 3, item 3
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$600$300Apr 12, 1996Final
Citation 3, item 4
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$750$375Apr 12, 1996Final

Inspection 126484476 OPENED FEB 5, 1996Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 28, 1996

100 Woodcross Dr, Columbia, SC 29212 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 30005 D
Other-than-serious$0$0Feb 22, 1996Closed

Inspection 126473172 OPENED JUL 10, 1995Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jul 21, 1995

7366 Garners Ferry Rd., Columbia, SC 29202 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$0$0Jul 21, 1995Closed
Citation 1, item 1b
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Jul 21, 1995Closed

Inspection 124653221 OPENED MAR 28, 1995Closed

Follow-up · Partial · Safety · 5 employees at the site · Closed Feb 2, 1996

Wild Dunes, Isle Of Palms, SC 29451 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 124676982 OPENED NOV 15, 1994Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 15, 1996

Columbiana Drive, Columbia, SC 29210 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 3, item 1
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$875$875Nov 29, 1994Closed
Citation 3, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$875$875Nov 29, 1994Closed

Inspection 124666918 OPENED SEP 14, 1994Closed

Planned · Complete · Safety · 8 employees at the site · Closed Feb 2, 1996

Wild Dunes, Isle Of Palms, SC 29451 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 10012 A
Serious$625$625Oct 11, 1994Closed
Citation 1, item 2
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$625$625Oct 11, 1994Closed
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$625$625Oct 11, 1994Closed
Citation 2, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Oct 11, 1994Closed

Inspection 124661992 OPENED JUN 1, 1994Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jan 9, 1995

2930 Devine St., Columbia, SC 29205 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$375$150Jun 10, 1994Closed
Citation 1, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$2,000$800Jun 10, 1994Closed
Citation 1, item 3
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$375$150Jun 10, 1994Closed
Citation 1, item 4a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$500$200Jun 10, 1994Closed
Citation 1, item 4b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Jun 10, 1994Closed
Citation 1, item 4c
29 CFR 1926.404(f)(7)(ivc)(2) · Ground-fault protection on job sites
Serious$0$0Jun 10, 1994Closed

Inspection 120468418 OPENED APR 14, 1993Closed

Planned · Complete · Safety · 3 employees at the site · Closed Dec 1, 1993

7366 Garners Ferry Rd., Columbia, SC 29202 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 10012 A
Serious$1,500$600May 14, 1993Closed
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$525$210May 14, 1993Closed
Citation 1, item 3
29 CFR 1926.451(d)(4) · Scaffolds, general requirements
Serious$375$150May 14, 1993Closed
Citation 1, item 4
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,500$600May 14, 1993Closed
Citation 2, item 1
29 CFR 1926.50(c) · Medical services and first aid
Other-than-serious$0$0May 14, 1993Closed
Citation 2, item 2
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0May 14, 1993Closed
Citation 2, item 3
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0May 14, 1993Closed

Inspection 105453344 OPENED JUL 31, 1990Closed

Planned · Complete · Safety · 4 employees at the site · Closed Oct 15, 1990

2005 Beltline Blvd., Columbia, SC 29206 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Aug 30, 1990Closed
Citation 1, item 2
29 CFR 1926.59(e)(1)(i) · Hazard communication
Other-than-serious$0$0Aug 30, 1990Closed
Citation 1, item 3
29 CFR 1926.59(e)(2) · Hazard communication
Other-than-serious$0$0Aug 30, 1990Closed
Citation 1, item 4
29 CFR 1926.59(g)(1) · Hazard communication
Other-than-serious$0$0Aug 30, 1990Closed
Citation 1, item 5
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0Aug 30, 1990Closed
Citation 1, item 6
29 CFR 1926.451(e)(3) · Scaffolds, general requirements
Other-than-serious$0$0Aug 30, 1990Closed
Citation 1, item 7
29 CFR 1926.451(e)(4) · Scaffolds, general requirements
Other-than-serious$0$0Aug 30, 1990Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.59 · Hazard communication

Other drywall and insulation contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.