OSHA SearchOSHA records by employer

Direct Colors: OSHA inspections and violations

Shawnee, Oklahoma · Synthetic Dye and Pigment Manufacturing · NAICS 325130

2inspections
13citation items
$16,250current penalties
Apr 18, 2024last inspection

OSHA has inspected Direct Colors 2 times in Oklahoma since 2024.

The latest one began on Apr 18, 2024 after a complaint, in Shawnee.

Those inspections ended with 13 citation items: 11 serious and 2 other-than-serious.

Penalties were first proposed at $40,564 and now stand at $16,250, 60% lower after settlements or reviews.

Flammable liquids comes up most often in these citations: 5 items under 1910.106.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Direct Colors averages $8,125 (2 cited inspections).

Direct Colors: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Direct Colors again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347427098 OPENED APR 18, 2024Closed

Complaint · Partial · Health · 17 employees at the site · Closed Oct 29, 2024

430 East 10th Street, Shawnee, OK 74801 · Synthetic Dye and Pigment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.38(b) · Emergency action plans
Other-than-serious$3,687$1,250Sep 24, 2024Final

Inspection 347298465 OPENED FEB 22, 2024Closed

Complaint · Partial · Health · 17 employees at the site · Closed Jan 16, 2025

430 East 10th Street, Shawnee, OK 74801 · Synthetic Dye and Pigment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$4,610$2,200Aug 15, 2024Final
Citation 1, item 2a
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$4,610$2,200Aug 15, 2024Final
Citation 1, item 2b
29 CFR 1910.106(e)(3)(v)(a) · Flammable liquids
Serious$0$0Aug 15, 2024Final
Citation 1, item 2c
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$4,610$0Aug 15, 2024Final
Citation 1, item 2d
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$0$0Aug 15, 2024Final
Citation 1, item 4
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$4,610$2,200Aug 15, 2024Final
Citation 1, item 5
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$3,687$2,000Aug 15, 2024Final
Citation 1, item 6
29 CFR 1910.151(c) · First aid and eyewash
Serious$4,610$2,200Aug 15, 2024Final
Citation 1, item 7
29 CFR 1910.178(c)(2)(xii) · Forklifts and other powered industrial trucks
Serious$4,610$2,200Aug 15, 2024Final
Citation 1, item 8
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$2,765$1,000Aug 15, 2024Final
Citation 1, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,765$1,000Aug 15, 2024Final
Citation 2, item 1
29 CFR 1904.32(b)(6) · Yearly injury summary
Other-than-serious$0$0Aug 15, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(b)(6)

(6) When do I have to post the annual summary? You must post the summary no later than February 1 of the year following the year covered by the records and keep the posting in place until April 30.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.38 · Emergency action plans

Other synthetic dye and pigment manufacturing employers in Oklahoma