5inspections
9citation items
$3,330current penalties
Oct 27, 2015last inspection

OSHA has inspected Donnelly Custom Manufacturing Company 5 times in Minnesota since 1994.

The latest one began on Oct 27, 2015 as a planned inspection, in Alexandria.

Those inspections ended with 9 citation items: 2 serious and 7 other-than-serious.

Penalties were first proposed at $4,500 and now stand at $3,330, 26% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Donnelly Custom Manufacturing Company averages $1,050 (1 cited inspection).

Donnelly Custom Manufacturing Company: OSHA citation items per year, 1994 to 2015
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

374employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Donnelly Custom Manufacturing Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341149441 OPENED OCT 27, 2015Closed

Planned · Complete · Safety · 220 employees at the site · Closed Nov 25, 2015

105 Donovan Dr, Alexandria, MN 56308 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$1,200$840Nov 5, 2015Final
Citation 2, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$300$210Nov 5, 2015Final

Inspection 316680982 OPENED SEP 4, 2012Closed

Planned · Complete · Safety · 220 employees at the site · Closed Sep 25, 2012

105 Donovan Dr, Alexandria, MN 56308 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$1,500$1,050Sep 12, 2012Closed
Citation 2, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$300$210Sep 12, 2012Closed
Citation 2, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$300$210Sep 12, 2012Closed
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$300$210Sep 12, 2012Closed

Inspection 309117752 OPENED AUG 2, 2005Closed

Planned · Complete · Safety · 230 employees at the site · Closed Aug 2, 2005

105 Donovan, Alexandria, MN 56308 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307510255 OPENED MAY 17, 2004Closed

Planned · No inspection · Safety · 220 employees at the site · Closed May 17, 2004

105 Donovan, Alexandria, MN 56308 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 120384490 OPENED JUN 3, 1994Closed

Complaint · Complete · Health · 180 employees at the site · Closed Sep 21, 1994

105 Donovan, Alexandria, MN 56308 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Aug 4, 1994Closed
Citation 1, item 2 Other-than-serious$200$200Aug 4, 1994Closed
Citation 1, item 3 Other-than-serious$400$400Aug 4, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(e)(4)(iii)

(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(p)(1)

(p) Operation of the truck. (1) If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.215(b)(9)

(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)

29 CFR 1910.305 · Electrical wiring methods

29 CFR 5206.700

29 CFR 5210.630

Other all other plastics product manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.