OSHA SearchOSHA records by employer

Dunbarton Corporation: OSHA inspections and violations

Camden, Tennessee · Wood Window and Door Manufacturing · NAICS 321911

3inspections
15citation items
$7,625current penalties
Jul 17, 2018last inspection

Since 2013, OSHA inspectors have visited Dunbarton Corporation in Tennessee 3 times.

The most recent inspection opened on Jul 17, 2018 to follow up on an earlier case, in Camden.

In all, OSHA issued 15 citation items: 1 serious, 4 repeat and 10 other-than-serious.

The penalties, $7,625 in total, stand where OSHA first set them.

The rule cited most here is 1910.1200 (hazard communication), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Dunbarton Corporation averages $4,025 across 1 cited inspection.

Dunbarton Corporation: OSHA citation items per year, 2013 to 2018
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

342employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Dunbarton Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343303327 OPENED JUL 17, 2018Closed

Follow-up · Partial · Safety · 11 employees at the site · Closed Jul 26, 2018

555 Benton Industrial Road, Camden, TN 38320 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343099511 OPENED APR 19, 2018Closed

Planned · Complete · Safety · 11 employees at the site · Closed May 31, 2018

555 Benton Industrial Road, Camden, TN 38320 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Repeat$2,800$2,800May 8, 2018Final
Citation 2, item 1
29 CFR 1910.242(b) · Hand and power tools
Repeat$350$350May 8, 2018Final
Citation 2, item 2
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Repeat$350$350May 8, 2018Final
Citation 2, item 3
29 CFR TDLWD RULE 800-01-09-.07
Repeat$350$350May 8, 2018Final
Citation 3, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$175$175May 8, 2018Final

Inspection 317223279 OPENED JUL 2, 2013Closed

Planned · Complete · Safety · 23 employees at the site · Closed Oct 14, 2013

555 Benton Industrial Blvd, Camden, TN 38320 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(iva) · Flammable liquids
Serious$1,600$1,600Aug 5, 2013Closed
Citation 2, item 2
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$200$200Aug 5, 2013Closed
Citation 2, item 3
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$400$400Aug 5, 2013Closed
Citation 2, item 4
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$200$200Aug 5, 2013Closed
Citation 2, item 5
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$200$200Aug 2, 2013Closed
Citation 2, item 6
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$200$200Aug 5, 2013Closed
Citation 2, item 7
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$200$200Aug 5, 2013Closed
Citation 2, item 8
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$200$200Aug 5, 2013Closed
Citation 2, item 9
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$200$200Aug 5, 2013Closed
Citation 2, item 11
29 CFR 90007
Other-than-serious$200$200Aug 5, 2013Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.106(e)(2)(iva)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.305 · Electrical wiring methods

Other wood window and door manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.