Howard Lake, Minnesota · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110
24inspections
60citation items
$20,761current penalties
Feb 3, 2026last inspection
Dura-Supreme LLC has 24 OSHA inspections on record in Minnesota, the first in 1974.
OSHA's last visit started on Feb 3, 2026 as a planned inspection, in Howard Lake.
Across those inspections OSHA issued 60 citation items: 17 serious, 1 repeat and 42 other-than-serious.
OSHA proposed $33,543 in penalties. After settlements and reviews the total is $20,761, down 38%.
Most often, OSHA cited 1910.213, woodworking machinery (10 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Dura-Supreme LLC averages $3,700 over 3 cited inspections in that time.
Dura-Supreme LLC also files yearly injury logs with OSHA, summarized below.
The Wage and Hour Division has 1 case on it since 2015, with $873 in back wages owed to workers.
Citation items per year, by inspection date.
Minnesota · latest 90 days of OSHA records
369employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Howard Lake site logged 8 recordable injuries or illnesses among about 521 workers: 1.6 per 100 full-time workers, against a median of 3.7 for its industry. Those cases cost 154 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Dura Supreme
Howard Lake · 2025
521
8
5
1.6
3.7
Included with any plan: 3 more yearly logs from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
29 CFR 1910.106(e)(6)(i)
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.