OSHA SearchOSHA records by employer

E & C Precast Concrete Inc: OSHA inspections and violations

Littleton, Colorado · Brick, Stone, and Related Construction Material Merchant Wholesalers · NAICS 423320

2inspections
7citation items
$2,930current penalties
Feb 28, 2024last inspection

OSHA has inspected E & C Precast Concrete Inc 2 times in Colorado since 1986.

The latest one began on Feb 28, 2024 as a planned inspection, in Littleton.

Those inspections ended with 7 citation items: 3 serious and 4 other-than-serious.

Penalties were first proposed at $4,883 and now stand at $2,930, 40% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 3 items under 1910.134.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,424, and E & C Precast Concrete Inc averages $2,930 (1 cited inspection).

E & C Precast Concrete Inc also files yearly injury logs with OSHA, summarized below.

E & C Precast Concrete Inc: OSHA citation items per year, 1986 to 2024
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch E & C Precast Concrete Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347311086 OPENED FEB 28, 2024Closed

Planned · Partial · Health · 33 employees at the site · Closed Jan 6, 2025

9608 North Moore Road, Littleton, CO 80125 · Brick, Stone, and Related Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,113$2,468Jul 30, 2024Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jul 30, 2024Final
Citation 1, item 1c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Jul 30, 2024Final
Citation 2, item 1 Other-than-serious$770$462Jul 30, 2024Final
Citation 2, item 2
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jul 30, 2024Final
Citation 2, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 30, 2024Final
Citation 2, item 4
29 CFR 1910.1053(d)(4) · Silica dust in general industry
Other-than-serious$0$0Jul 30, 2024Final

Inspection 101700375 OPENED OCT 24, 1986Closed

Planned · No inspection · Safety · 10 employees at the site · Closed Oct 27, 1986

13200 Titan Rd. S., Littleton, CO 80125 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Littleton site logged 0 recordable injuries or illnesses among about 29 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
E&C Precast, Concrete, Inc.
Littleton · 2025
29 000.02.8
E&C Precast Concrete, Inc.
Littleton · 2023
29 207.13.4

Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(d)(4)

(4) Reassessment of exposures. The employer shall reassess exposures whenever a change in the production, process, control equipment, personnel, or work practices may reasonably be expected to result in new or additional exposures at or above the action level, or when the employer has any reason to believe that new or additional exposures at or above the action level have occurred.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.25 · Stairways

29 CFR 1910.303 · Electrical equipment, general requirements

Other brick, stone, and related construction material merchant wholesalers employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.