E.T Mackenzie of Florida Inc: OSHA inspections and violations
Nokomis, Florida · Water and Sewer Line and Related Structures Construction · NAICS 237110
3inspections
9citation items
$65,185current penalties
Jan 28, 2025last inspection
E.T Mackenzie of Florida Inc has 3 OSHA inspections on record in Florida, the first in 2002.
OSHA's last visit started on Jan 28, 2025 after a complaint, in Bradenton.
Across those inspections OSHA issued 9 citation items: 5 serious, 2 willful and 2 other-than-serious.
OSHA proposed $89,339 in penalties. After settlements and reviews the total is $65,185, down 27%.
Most often, OSHA cited 1926.21, construction safety training (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. E.T Mackenzie of Florida Inc averages $8,542 over 2 cited inspections in that time.
1 inspection on this page followed a fatal incident.
E.T Mackenzie of Florida Inc also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Florida · latest 90 days of OSHA records
315employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch E.T Mackenzie of Florida Inc and get notified the morning OSHA posts a new citation for it.
Incident on Mar 29, 2002 (fatal): Employee drown in lift station
On March 29, 2002, Employees were in the process of constructing a new lift stat ion (10 ft in diameter by 25 ft deep) and modifying an existing lift station (4 ft diameter by 23 ft deep) that was a temporary station for a new sub-division i n the process of being developed. The temporary lift station had a gravity feed line at the bottom of the pit (approximately 23 ft) along with a newly installed 18 in. line attached at 18 ft deep that would gravity feed into the new lift st ation. Two grinder pumps were at the bottom of the temporary lift station attach ed to pvc pipes located approximately 3 ft from the top of the manhole feeding i nto a high pressure (discharge) main. Employee #1 was in the process of "bucketi ng" the water out of the temporary lift station, when the bucket slipped and fel l back into the manhole, breaking the pvc discharge pipe in back of the check va lve and allowing the sewage to free flow into the lift station from the high pre ssure main. Coworker worker shut the valve off from the road, but the manhole fi lled approximately two-thirds of the way. Employee #2 had Employee #1 enter the manhole to repair the broken pvc pipe while the Foreman stood by watching. Less than a minute after Employee #1 entered the confined space, he realized there wa s a problem with the air. Employee #1 started feeling dizzy, dropped his tools a nd then (apparently) went unconscious and fell into the septic liquid below. Emp loyee #2 quickly entered the manhole to rescue Employee #1. Employee #3 climbed in with a rope to assist Employee #2. Employee #2 found Employee #1 and the two rescuers were able to tie a rope around Employee #1. Once he was lifted out of t he manhole, Employee #2 was not visible. Employee #3 was too weak to search for Employee #2 and was assisted out of the lift station. Employee #2 was still not visible. The Fire Department arrived, but had to wait for the Special Operations Unit to arrive. The Foreman became frustrated and allowed a coworker to enter t he lift station with a rope. He was able to locate Employee #2, tie a rope aroun d him and retrieve the body. Employee #1 died.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Bradenton site logged 6 recordable injuries or illnesses among about 213 workers: 2.3 per 100 full-time workers, against a median of 0.1 for its industry. Those cases cost 101 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
E.T. MacKenzie of Florida, Inc.
Bradenton · 2025
213
6
2
2.3
0.1
Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.
(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.