OSHA SearchOSHA records by employer

East Coast Concrete Products LLC: OSHA inspections and violations

Milford, Connecticut · Concrete Block and Brick Manufacturing · NAICS 327331

2inspections
34citation items
$9,121current penalties
Oct 30, 2024last inspection

OSHA has inspected East Coast Concrete Products LLC 2 times in Connecticut since 2005.

The latest one began on Oct 30, 2024 after a complaint, in Milford.

Those inspections ended with 34 citation items: 32 serious and 2 other-than-serious.

Penalties were first proposed at $14,587 and now stand at $9,121, 37% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 5 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and East Coast Concrete Products LLC averages $2,581 (1 cited inspection).

East Coast Concrete Products LLC: OSHA citation items per year, 2005 to 2024
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

86employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch East Coast Concrete Products LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347850240 OPENED OCT 30, 2024Closed

Complaint · Partial · Health · 12 employees at the site · Closed Jan 23, 2025

24 Honek Street, Milford, CT 06460 · Concrete Block and Brick Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,687$2,581Nov 7, 2024Final
Citation 2, item 1
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Nov 7, 2024Final

Inspection 309375533 OPENED DEC 28, 2005Closed

Referral · Partial · Safety · 12 employees at the site · Closed May 16, 2007

24 Honek Street, Milford, CT 06460 · Concrete Block and Brick Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$600$360Jan 31, 2006Closed
Citation 1, item 2
29 CFR 1910.23(c)(3) · Guarding floor and wall openings and holes
Serious$600$360Jan 31, 2006Closed
Citation 1, item 3
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Serious$450$270Jan 31, 2006Closed
Citation 1, item 4a
29 CFR 1910.36(d)(1) · Exit route design
Serious$750$450Jan 31, 2006Closed
Citation 1, item 4b
29 CFR 1910.36(e)(1) · Exit route design
Serious$0$0Jan 31, 2006Closed
Citation 1, item 4c
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Jan 31, 2006Closed
Citation 1, item 4d
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Jan 31, 2006Closed
Citation 1, item 5a
29 CFR 1910.38(a)(1) · Emergency action plans
Serious$450$270Jan 31, 2006Closed
Citation 1, item 5b
29 CFR 1910.39(a) · Fire prevention plans
Serious$0$0Jan 31, 2006Closed
Citation 1, item 6a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$600$360Jan 31, 2006Closed
Citation 1, item 6b
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Serious$0$0Jan 31, 2006Closed
Citation 1, item 7a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,500$900Jan 31, 2006Closed
Citation 1, item 7b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Jan 31, 2006Closed
Citation 1, item 7c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Jan 31, 2006Closed
Citation 1, item 8a
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$450$270Jan 31, 2006Closed
Citation 1, item 8b
29 CFR 1910.157(e)(1) · Portable fire extinguishers
Serious$0$0Jan 31, 2006Closed
Citation 1, item 9
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$600$360Jan 31, 2006Closed
Citation 1, item 10
29 CFR 1910.212(a)(1) · Machine guarding
Serious$750$450Jan 31, 2006Closed
Citation 1, item 11
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$600$360Jan 31, 2006Closed
Citation 1, item 12a
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Serious$750$450Jan 31, 2006Closed
Citation 1, item 12b
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$0$0Jan 31, 2006Closed
Citation 1, item 13a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$600$360Jan 31, 2006Closed
Citation 1, item 13b
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Jan 31, 2006Closed
Citation 1, item 13c
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jan 31, 2006Closed
Citation 1, item 14a
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$600$360Jan 31, 2006Closed
Citation 1, item 14b
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Jan 31, 2006Closed
Citation 1, item 14c
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Jan 31, 2006Closed
Citation 1, item 14d
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Jan 31, 2006Closed
Citation 1, item 14e
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jan 31, 2006Closed
Citation 1, item 15a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$600$360Jan 31, 2006Closed
Citation 1, item 15b
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Jan 31, 2006Closed
Citation 2, item 1
29 CFR 1904.29(a) · Injury and illness log
Other-than-serious$1,000$600Jan 30, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(a)

(a) Basic requirement. You must use OSHA 300, 300-A, and 301 forms, or equivalent forms, for recordable injuries and illnesses. The OSHA 300 form is called the Log of Work-Related Injuries and Illnesses, the 300-A is the Summary of Work-Related Injuries and Illnesses, and the OSHA 301 form is called the Injury and Illness Incident Report.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(f)(2)(i)

(2) General. (i) Containers in storage shall be located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.39 · Fire prevention plans

Other concrete block and brick manufacturing employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.