Waco, Texas · Metal Window and Door Manufacturing · NAICS 332321
3inspections
8citation items
$20,535current penalties
Feb 19, 2020last inspection
OSHA has inspected Elixir Door & Metals Company 3 times in Texas since 2019.
The latest one began on Feb 19, 2020 to follow up on an earlier case, in Waco.
Those inspections ended with 8 citation items: 5 serious and 3 other-than-serious.
Penalties were first proposed at $31,499 and now stand at $20,535, 35% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 2 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Elixir Door & Metals Company averages $6,845 (3 cited inspections).
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Texas · latest 90 days of OSHA records
399employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Elixir Door & Metals Company and get notified the morning OSHA posts a new citation for it.
OSHA records show Elixir Door & Metals Company at 4 sites in 3 states. Together they've had 12 inspections and $82,798 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Incident on Mar 12, 2019: Machine operator's finger is amputated while operating crimp
At 11:45 a.m. on March 12, 2019, an employee was working for a firm that manufactured metal windows and doors. He was operating a crimping machine, or crimper. The machine became jammed. When the employee attempted to clear the jam, his finger became caught. He suffered an amputation. He was hospitalized.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.