OSHA SearchOSHA records by employer

Energy Transfer: OSHA inspections and violations

Canfield, Ohio · Fabricated Pipe and Pipe Fitting Manufacturing · NAICS 332996

7inspections
49citation items
$31,212current penalties
Dec 12, 2019last inspection

OSHA has inspected Energy Transfer 7 times in Ohio since 1985.

The latest one began on Dec 12, 2019, in Minerva.

Those inspections ended with 49 citation items: 33 serious, 2 repeat and 14 other-than-serious.

Penalties were first proposed at $61,625 and now stand at $31,212, 49% lower after settlements or reviews.

Lead in general industry comes up most often in these citations: 23 items under 1910.1025.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Energy Transfer averages $5,000 (1 cited inspection).

Energy Transfer: OSHA citation items per year, 1985 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Energy Transfer again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344518477 OPENED DEC 12, 2019Closed

Unprogrammed other · Complete · Safety · 85 employees at the site · Closed Jun 15, 2020

9312 Arrow Road Nw, Minerva, OH 44657 · Metalworking Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$5,000Apr 6, 2020Final

Inspection 332425008 OPENED FEB 9, 2012Closed

Follow-up · Partial · Safety · 58 employees at the site · Closed Jun 7, 2013

1100 Steubenville Rd Se, Carrollton, OH 44615 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b) · Exit routes
Other-than-serious$0$0Mar 8, 2012Final

Inspection 331900258 OPENED JAN 24, 2012Closed

Complaint · Partial · Health · 58 employees at the site · Closed Jan 24, 2012

1100 Steubenville Rd Se, Carrollton, OH 44615 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307374777 OPENED JAN 21, 2004Closed

Planned · Partial · Safety · 14 employees at the site · Closed Mar 3, 2004

451 W. Main Street, Canfield, OH 44406 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$500$350Jan 28, 2004Closed
Citation 1, item 1b
29 CFR 1910.212(a)(1) · Machine guarding
Serious$0$0Jan 28, 2004Closed
Citation 1, item 2a
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$375$262Jan 28, 2004Closed
Citation 1, item 2b
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$0$0Jan 28, 2004Closed
Citation 1, item 2c
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Serious$0$0Jan 28, 2004Closed
Citation 1, item 2d
29 CFR 1910.179(n)(4)(i) · Overhead and gantry cranes
Serious$0$0Jan 28, 2004Closed

Inspection 121935035 OPENED OCT 24, 1995Closed

Complaint · Partial · Health · 24 employees at the site · Closed Sep 24, 1997

451 W. Main Street, Canfield, OH 44406 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Nov 30, 1995Closed
Citation 1, item 2
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Nov 30, 1995Closed
Citation 2, item 1a
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$3,000$1,500Mar 19, 1996Final
Citation 2, item 1b
29 CFR 1910.134(b)(9) · Respiratory protection
Other-than-serious$0$0Mar 19, 1996Final
Citation 2, item 2a
29 CFR 1910.1025(g)(2)(v) · Lead in general industry
Other-than-serious$3,000$1,500Mar 19, 1996Final
Citation 2, item 2b
29 CFR 1910.1025(g)(2)(vii) · Lead in general industry
Other-than-serious$0$0Mar 19, 1996Final
Citation 2, item 3
29 CFR 1910.1025(i)(3)(iii) · Lead in general industry
Other-than-serious$3,000$1,500Mar 19, 1996Final
Citation 3, item 2
29 CFR 1910.1025(d)(7) · Lead in general industry
Repeat$6,000$3,000Mar 19, 1996Final
Citation 3, item 3
29 CFR 1910.1025(e)(5)(i) · Lead in general industry
Repeat$6,000$3,000Mar 19, 1996Final

Inspection 103512380 OPENED FEB 10, 1994Closed

Referral · Partial · Health · 42 employees at the site · Closed Jun 20, 1995

451 W. Main Street, Canfield, OH 44406 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(b) · First aid and eyewash
Serious$1,000$600Apr 26, 1994Closed
Citation 1, item 2
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$1,000$600Apr 26, 1994Closed
Citation 1, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$1,000$600Apr 26, 1994Closed
Citation 1, item 4
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$750$450Apr 26, 1994Closed
Citation 1, item 5a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,000$600Apr 26, 1994Closed
Citation 1, item 5b
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Apr 26, 1994Closed
Citation 1, item 5c
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Apr 26, 1994Closed
Citation 1, item 5d
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Apr 26, 1994Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Apr 26, 1994Closed
Citation 2, item 2 Other-than-serious$0$0Apr 26, 1994Closed
Citation 2, item 3
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Apr 26, 1994Closed
Citation 2, item 4
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Apr 26, 1994Closed
Citation 2, item 5
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Apr 26, 1994Closed
Citation 2, item 6
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Apr 26, 1994Closed
Citation 3, item 1a
29 CFR 1910.1025(c)(1) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 1b
29 CFR 1910.1025(e)(1) · Lead in general industry
Serious$0$0Jun 9, 1994Closed
Citation 3, item 2
29 CFR 1910.1025(d)(6)(iii) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 3a
29 CFR 1910.1025(e)(3)(i) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 3b
29 CFR 1910.1025(e)(5)(i) · Lead in general industry
Serious$0$0Jun 9, 1994Closed
Citation 3, item 4a
29 CFR 1910.1025(f)(1) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 4b
29 CFR 1910.1025(f)(4)(i) · Lead in general industry
Serious$0$0Jun 9, 1994Closed
Citation 3, item 5a
29 CFR 1910.1025(g)(2)(ii) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 5b
29 CFR 1910.1025(g)(2)(vi) · Lead in general industry
Serious$0$0Jun 9, 1994Closed
Citation 3, item 6
29 CFR 1910.1025(h)(2)(ii) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 7
29 CFR 1910.1025(i)(1) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 8a
29 CFR 1910.1025(i)(2)(ii) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 8b
29 CFR 1910.1025(i)(3)(ii) · Lead in general industry
Serious$0$0Jun 9, 1994Closed
Citation 3, item 8c
29 CFR 1910.1025(i)(4)(iv) · Lead in general industry
Serious$0$0Jun 9, 1994Closed
Citation 3, item 9
29 CFR 1910.1025(j)(1)(i) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 10a
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Serious$3,500$1,225Jun 9, 1994Closed
Citation 3, item 10b
29 CFR 1910.1025(l)(1)(iii) · Lead in general industry
Serious$0$0Jun 9, 1994Closed
Citation 3, item 10c
29 CFR 1910.1025(l)(2)(i) · Lead in general industry
Serious$0$0Jun 9, 1994Closed

Inspection 100067834 OPENED JUL 5, 1985Closed

Planned · No inspection · Safety · 5 employees at the site · Closed Jul 5, 1985

445 W Main St, Canfield, OH 44406 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(c)(1)

(c) Permissible exposure limit (PEL). (1) The employer shall assure that no employee is exposed to lead at concentrations greater than fifty micrograms per cubic meter of air (50 µg/m 3) averaged over an 8-hour period.

29 CFR 1910.1025(d)(6)(iii)

(iii) If the initial monitoring reveals that employee exposure is above the permissible exposure limit the employer shall repeat monitoring quarterly. The employer shall continue monitoring at the required frequency until at least two consecutive measurements, taken at least 7 days apart, are below the PEL but at or above the action level at which time the employer shall repeat monitoring for that employee at the frequency specified in paragraph (d)(6)(ii), except as otherwise provided in paragraph (d)(7) of this section.

29 CFR 1910.1025(d)(7)

(7) Additional monitoring. Whenever there has been a production, process, control or personnel change which may result in new or additional exposure to lead, or whenever the employer has any other reason to suspect a change which may result in new or additional exposures to lead, additional monitoring in accordance with this paragraph shall be conducted.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.20

29 CFR 1910.212 · Machine guarding

29 CFR 1910.22 · General requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other fabricated pipe and pipe fitting manufacturing employers in Ohio

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.