OSHA SearchOSHA records by employer

Esw America Inc: OSHA inspections and violations

Telford, Pennsylvania · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

5inspections
30citation items
$10,984current penalties
Nov 22, 2022last inspection

OSHA has inspected Esw America Inc 5 times in Pennsylvania since 2005.

The latest one began on Nov 22, 2022 after a complaint, in Montgomeryville.

Those inspections ended with 30 citation items: 25 serious, 1 repeat and 4 other-than-serious.

Penalties were first proposed at $17,737 and now stand at $10,984, 38% lower after settlements or reviews.

Mechanical power presses comes up most often in these citations: 6 items under 1910.217.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Esw America Inc averages $1,708 (1 cited inspection).

Esw America Inc: OSHA citation items per year, 2005 to 2022
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

280employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Esw America Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346354301 OPENED NOV 22, 2022Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Apr 28, 2023

200 Progress Drive, Montgomeryville, PA 18936 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$2,277$1,708Mar 23, 2023Final

Inspection 314721283 OPENED NOV 23, 2010Closed

Complaint · Partial · Health · 8 employees at the site · Closed Nov 23, 2010

200 Progress Drive, Montgomeryville, PA 18936 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312976418 OPENED NOV 25, 2009Closed

Planned · No inspection · Safety · Closed Dec 29, 2009

132 Penn Ave, Telford, PA 18969 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308171974 OPENED AUG 22, 2005Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Mar 15, 2006

132 Penn Ave, Telford, PA 18969 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$800$480Nov 3, 2005Closed
Citation 1, item 2
29 CFR 1910.212(a)(4) · Machine guarding
Serious$800$480Nov 3, 2005Closed
Citation 1, item 3
29 CFR 1910.217(b)(1) · Mechanical power presses
Serious$510$306Nov 3, 2005Closed
Citation 1, item 4
29 CFR 1910.217(b)(3)(i) · Mechanical power presses
Serious$2,000$1,200Nov 3, 2005Closed
Citation 1, item 5a
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Serious$800$480Nov 3, 2005Closed
Citation 1, item 5b
29 CFR 1910.217(b)(4)(ii) · Mechanical power presses
Serious$0$0Nov 3, 2005Closed
Citation 1, item 6
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$2,000$1,200Nov 3, 2005Closed
Citation 1, item 7
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$510$306Nov 3, 2005Closed
Citation 1, item 8a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$510$306Nov 3, 2005Closed
Citation 1, item 8b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 3, 2005Closed
Citation 1, item 9
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$510$306Nov 3, 2005Closed
Citation 2, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Repeat$2,800$1,680Nov 3, 2005Closed

Inspection 308174002 OPENED AUG 22, 2005Closed

Complaint · Complete · Health · 20 employees at the site · Closed Mar 15, 2006

132 Penn Ave, Telford, PA 18969 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$800$480Oct 27, 2005Closed
Citation 1, item 1b Serious$0$0Oct 27, 2005Closed
Citation 1, item 1c Serious$0$0Oct 27, 2005Closed
Citation 1, item 2a
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$510$306Oct 27, 2005Closed
Citation 1, item 2b
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$0$0Oct 27, 2005Closed
Citation 1, item 3
29 CFR 1910.134(e)(2)(ii) · Respiratory protection
Serious$800$480Oct 27, 2005Closed
Citation 1, item 4
29 CFR 1910.151(c) · First aid and eyewash
Serious$510$306Oct 27, 2005Closed
Citation 1, item 5a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$800$480Oct 27, 2005Closed
Citation 1, item 5b
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Serious$0$0Oct 27, 2005Closed
Citation 1, item 5c
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Oct 27, 2005Closed
Citation 1, item 6a
29 CFR 1910.1200(d)(1) · Hazard communication
Serious$800$480Oct 27, 2005Closed
Citation 1, item 6b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Oct 27, 2005Closed
Citation 1, item 6c
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Oct 27, 2005Closed
Citation 2, item 1 Other-than-serious$0$0Oct 27, 2005Closed
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 27, 2005Closed
Citation 2, item 3
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 27, 2005Closed
Citation 2, item 4
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Oct 27, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(e)(2)

(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other all other miscellaneous fabricated metal product manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.