OSHA SearchOSHA records by employer

Ethan Coop Lumber Association: OSHA inspections and violations

Ethan, South Dakota · Commercial and Institutional Building Construction · NAICS 236220

2inspections
11citation items
$2,300current penalties
Jan 20, 2017last inspection

Ethan Coop Lumber Association has 2 OSHA inspections on record in South Dakota, the first in 1976.

OSHA's last visit started on Jan 20, 2017, in Salem.

Across those inspections OSHA issued 11 citation items: 1 serious and 10 other-than-serious.

OSHA proposed $3,722 in penalties. After settlements and reviews the total is $2,300, down 38%.

Most often, OSHA cited 1910.23, ladders in general industry (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Ethan Coop Lumber Association averages $2,200 over 1 cited inspection in that time.

Ethan Coop Lumber Association: OSHA citation items per year, 1976 to 2017
Citation items per year, by inspection date.

South Dakota · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in South Dakota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Dakota

Checking a subcontractor, a client or your own company? Watch Ethan Coop Lumber Association and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342050515 OPENED JAN 20, 2017Closed

Unprogrammed other · Partial · Safety · 8 employees at the site · Closed Mar 8, 2017

25036 438th St., Salem, SD 57058 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$3,622$2,200Feb 1, 2017Final

Inspection 217950419 OPENED MAR 31, 1976Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jul 15, 1976

Ethan, Ethan, SD 57334 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Other-than-serious$25$25Apr 9, 1976Closed
Citation 1, item 2
29 CFR 1910.23(a)(1) · Guarding floor and wall openings and holes
Other-than-serious$25$25Apr 9, 1976Closed
Citation 1, item 3
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$25$25Apr 9, 1976Closed
Citation 1, item 4
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Apr 9, 1976Closed
Citation 1, item 5
29 CFR 1910.219(e)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Apr 9, 1976Closed
Citation 1, item 6
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$0$0Apr 9, 1976Closed
Citation 1, item 7
29 CFR 1910.213(h)(3) · Woodworking machinery
Other-than-serious$0$0Apr 9, 1976Closed
Citation 1, item 8
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Apr 9, 1976Closed
Citation 1, item 9 Other-than-serious$0$0Apr 9, 1976Closed
Citation 1, item 10 Other-than-serious$25$25Apr 9, 1976Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(h)(1)

(h) Radial saws. (1) The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.

29 CFR 1910.213(h)(3)

(3) An adjustable stop shall be provided to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations.

29 CFR 1910.213(h)(4)

(4) Installation shall be in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.309

29 CFR 1926.20 · Construction safety programs

Other commercial and institutional building construction employers in South Dakota

Alert subscribers get notified of each newly cited employer in South Dakota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.