OSHA SearchOSHA records by employer

Federal Foam Technologies, Inc. Industrial Div.: OSHA inspections and violations

New Richmond, Wisconsin · Urethane and Other Foam Product (except Polystyrene) Manufacturing · NAICS 326150

2inspections
9citation items
$9,245current penalties
Mar 28, 2017last inspection

Federal Foam Technologies, Inc. Industrial Div. has 2 OSHA inspections on record in Wisconsin, the first in 2003.

OSHA's last visit started on Mar 28, 2017 after a complaint, in New Richmond.

Across those inspections OSHA issued 9 citation items: 6 serious and 3 other-than-serious.

OSHA proposed $13,208 in penalties. After settlements and reviews the total is $9,245, down 30%.

Most often, OSHA cited 1910.147, lockout/tagout (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Federal Foam Technologies, Inc. Industrial Div. averages $7,985 over 1 cited inspection in that time.

Federal Foam Technologies, Inc. Industrial Div.: OSHA citation items per year, 2003 to 2017
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Federal Foam Technologies, Inc. Industrial Div. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342205663 OPENED MAR 28, 2017Closed

Complaint · Partial · Safety · 120 employees at the site · Closed Aug 10, 2017

600 Wisconsin Drive, New Richmond, WI 54017 · Urethane and Other Foam Product (except Polystyrene) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1910.147(d)(3) · Lockout/tagout
Serious$11,408$7,985Jul 12, 2017Final
Citation 1, item 2b
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Jul 12, 2017Final

Inspection 106054133 OPENED JAN 22, 2003Closed

Planned · Complete · Safety · 100 employees at the site · Closed Mar 18, 2003

600 Wisconsin Drive, New Richmond, WI 54017 · Urethane and Other Foam Product (except Polystyrene) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$1,125$788Jan 24, 2003Closed
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Jan 24, 2003Closed
Citation 1, item 1c Serious$0$0Jan 24, 2003Closed
Citation 1, item 2
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$675$472Jan 24, 2003Closed
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Jan 24, 2003Closed
Citation 2, item 2
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Jan 24, 2003Closed
Citation 2, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$0$0Jan 24, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.212 · Machine guarding

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.332 · Training

Other urethane and other foam product (except polystyrene) manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.